Warning – Hearth and Home Technologies C-40 User Manual

Page 5

Advertising
background image

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page 5

Improper installation, adjustment, alteration, ser-

vice or maintenance can cause injury or property

damage. Refer to the owner’s information manual

provided with this fireplace. For assistance or addi-

tional information consult a qualified installer, service

agency or your dealer.

WARNING

C. Glass Specifications

D. BTU & Efficiency Specifications

This fireplace is equipped with 5mm ceramic glass. Replace

glass only with 5mm ceramic glass. Please contact your

dealer for replacement glass.

NOTE: This installation must conform with local codes. In the

absence of local codes you must comply with the

UL1482, (UM)

84-HUD and NFPA211 in the U.S.A. and the ULC S627 and

CAN/CSA-B365 Installation Codes in Canada.

Hearth & Home Technologies disclaims any responsibility

for, and the warranty and agency listing will be voided by

the above actions.

Fire Risk

Do not install or operate damaged fireplace.

Do not modify fireplace.

• Installation other than as instructed by Hearth &

Home Technologies Inc. is strictly prohibited.

Do not operate the fireplace without fully assembling

all components.

Do not overfire.

Do not install an unvented gas log set. This

fireplace has not been tested for use with unvented

gas log sets.

• Installation and/or use of any component part not

approved by Hearth & Home Technologies.

WARNING

NOTE: Hearth & Home Technologies, manufacturer of

this appliance, reserves the right to alter its products,

their specifications and/or price without notice.

EPA Certified:

3.25 grams per hour

Efficiency:

up to 77.8%

BTU Output

with EPA test fuel:

with cord wood:

51,400/ hr.

70,000/hr

Vent Size:

8 inches

Firebox Size:

2.7 cubic feet

Max Wood Length:

24 inches

Fuel:

Cord Wood

Shipping Weight:

650 lbs