Heatilator • Constitution EPA Fireplace • 480-1091C

November 11, 2008

D. Assemble the Chimney Sections

Attach either a straight chimney section or an offset to the

top of the fireplace (depending on your installation require-

ment). Chimney sections are locked together by pushing

downward until the top section meets the stop bead on the

lower section.
The inner flue is placed to the inside of the flue section below

it. The outer casing is placed outside the outer casing of the

chimney section below it. See Figure 22.1.
If you are using a different approved venting system, follow

the instructions that were supplied with that system.

Note: Inner flue and outer liner sections cannot be

disassembled once locked together. Plan ahead to ensure

the proper installation height is achieved with the selected

chimney components.

Figure 22.1 Assembling Chimney Sections

Fire Risk
Do NOT install substitute or damaged

chimney components.

• MUST use chimney system described in

this manual.

• NO OTHER chimney components may

be used.

Substitute or damaged chimney components

may impair safe operation.

WARNING

E. Assembling Chimney Sections for the SL-

300 Series

NOTE: Chimney Air Kit, Part CAK4A is REqUIRED

when using the SL-300 Pipe Series. Detailed instruc-

tions are supplied with the kit.

Attach

Flue First

CAK4A

Secure with Screws

Provided

Push Together

Secure to Top

Installing CAK4A and Flex Pipe
NOTE: FOLLOW DETAILED INSTRUCTIONS THAT COME

WITH THE CAK4A.

1. Install the chimney pipe first.

2. Hand bend the tabs in position before placing on the

fireplace.

3. Place the box on top of the fireplace around the chimney

pipe, push both pieces together and secure with screws

provided.

4. Use the pre-punched holes in the tabs as guides and drill

holes through the fireplace top.

5. Secure the CAK4A in place.

6. Seal around the kit at the flue and at the top of the can

with caulk.

NOTES:

1. The outside termination cap must be a minimum of 6 ft

(1829 mm) above the ground and kept free of debris.

2. If the CAK4A is installed in a chase, the CAK4A side

termination cap must be at least 3 ft (914 mm) below the

chimney top.

3. Seal around the cap and flex with caulk to stop air from

getting in to the chase (See Figure 23.1 on page 23).

Figure 22.2 Installing the CAK4A

Fire Risk

• The flex hose must never be

compressed or deformed!

WARNING