Heatilator • Constitution EPA Fireplace • 480-1091C

November 11, 2008

7

Accessories

A. Fan Replacement

Screwdriver Slot

Screws

Unplug wire

harness before

removing fan

Remove nut

and lift out fan

Fan Cord Location

The Constitution Fireplace comes standard equipped with

two fans, installed at the factory with electric access on the

right side of fireplace (as you face it).

Shock Risk

Circulating Fireplace Only

• Do NOT remove grounding prong from

plug.

CAUTION

• Plug directly into properly grounded three-prong

receptacle.

• Route cord away from appliance.

• Do NOT route cord under or in front of appliance.

Figure 30.1 Accessing Fan Motor

Figure 30.2 Fan Motor

Removing the fan

1. Unplug the wire harness.
2. Lift fan from locating pins and remove. Repeat for second

fan if necessary. See Figure 30.2.

3. Connect new fan wires to wire harness.
4. Before installing the fan, make sure the grommets are

tightly in place. Insert the right fan and place over the 2

locating pins. Repeat for other fan. Figure 30.3.

5. Re-install bottom panel or firebox access panel in

reverse order as described above.

Fan Replacement Instructions

1. Remove the brick from the bottom of the fireplace and 3

of the back vertical bricks.

2. Remove the 2 screws from the access panel in the fire-

box floor. See Figure 30.1.

3. Pry up the access panel using the screwdriver slot and

completely remove the panel.

Figure 30.3 Installing Fans

6 Replace the brick that was removed.
7. Reconnect the power.

Shock Risk
Disconnect power by turning off circuit breaker

BEFORE servicing.

CAUTION