Hearth and Home Technologies C-40 User Manual

Page 29

Advertising
background image

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page 29

Storm Collar

Flashing Collar

Top of Pipe

14-1/2 in. (368mm) max.

1-1/2 in. (38 mm) min.

overlap

2 in. (51 mm) min.

Figure 29.1 Installing a TR342 Round Telescoping Termination Cap

2 in. (51 mm) min.

4-1/2 in.

(114 mm)

max.

1-1/2 in.

(38 mm) min.

overlap

Cap Standoff

Top of Pipe

Flashing Collar

Figure 29.2 Installing an ST375 Square Termination Cap

Top of Pipe

2 in.

(51 mm)

min.

Flashing

Collar

1-1/2 in.

(38 mm)

min.

overlap

3 in.

(76 mm)

max.

Figure 29.3 Installing a TS345/TS345P Square Termination Cap

For installations utilizing an ST375 Square Termination

Cap the last chimney section must not be more than

4-1/2 in. (114 mm) below the chase top. See Figure

29.2.

For installations utilizing a TS345/TS345P Square

Termination Cap, the uppermost chimney section must

not be more than 3 in. (76 mm) below the chase top. See

Figure 29.3.

For installations utilizing a Terra Cotta Cap the last chimney

section must be between 7 in. (178 mm) below the chase

top and 2 in. (51 mm) above. See Figure 29.4.

For chase installations you can use a Round Termination

Cap, a Round Telescoping Termination Cap, a Square

Termination Cap, or a Terra Cotta Termination Cap.

For installations utilizing a European Copper Series

Termination Cap, See Figure 29.5.

Install termination caps following instructions provided

with them.

chimney top

2 - 6 in.

(51-152 mm)

2 in. (51 mm)

typical

chase

top

(metal or masonry)

Cap Base

(cap inner flue)

SL pipe

inner flue

screw (8)*

bracket (8)

Figure 29.5 Installing a European Copper Series Termination Cap

(CT3-King shown)

The last section of pipe

must stop between the

distances given below.

2 in. (51 mm) above top

of the chase.

7 in. (178 mm) below top

of the chase.

{

Top of Pipe

1-1/2 in. (38 mm)

min. overlap

Figure 29.4 Installing a TCT375 Terra Cotta Cap

NOTE:

TR342/TR344: For less air restriction to flue

gases, use top vent kit listed in Section 12.

Advertising