Hearth and Home Technologies C-40 User Manual

Page 40

Advertising
background image

Page 40

Heatilator • Constitution EPA Fireplace • 480-1091C

November 11, 2008

Fascia

Outer Can

Flange

Ember Strip (Seal gap with

High temp, noncombustible

sealant able to withstand

300°)

Tile or

Marble

Minimum 2-1/4 in. (57mm) Cement Board

or equivalent, (or two 1/2 in. pieces)

and "k" value = 0.49. Micore 300

Minimum 20 in. (508mm) in front and

8 in. (203mm) on sides to fuel loading doors

Tile or

Marble

Combustible Floor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

Fascia

Outer

Can

Flange

Ember Strip (Seal gap

with high temp,

noncombustible sealant

able to withstand 300°)

Tile or Marble

Minimum 2-1/4 in.

57mm) Cement

Board or equivalent,

(or two 1/2 in. pieces)

and "k" value = 0.49.

Micore 300

Min 20 in. (508mm) in front and 8 in.

(203mm) on sides to fuel loading doors

Combustible

Floor

2 x 4

2 x 4

3/4 in.

(19mm)

Plywood

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fascia

Outer

Can

Flange

Ember Strip

(Seal gap with

noncombustible

sealant)

Tile or Marble

Minimum 2-1/4 in. (57mm)

Cement Board or equivalent,

(or two 1/2 in. pieces) and

"k" value = 0.49. Micore 300

Min 20 in. (508mm) in front and 8 in.

(203mm) on sides to fuel loading doors

Combustible Floor

2 x 4

2 x 4

3/4 in.

(19mm)

Plywood

Non-combustible

framing materials

Figure 40.1 Fireplace and Hearth Extension Flush on the Floor.

Figure 40.2 Fireplace and Hearth Extension Flush on Floor but on Raised Platform

Figure 40.3 Raised Hearth Extension to Bottom of Fascia

Advertising