Heatilator • Constitution EPA Fireplace • 480-1091C

Page 23

F. Install the Ceiling Firestops

• Mark and cut an opening in the ceiling for the ceiling

firestop being used. See Figure 23.2.

• Frame the opening with the same size lumber used in the

ceiling joists.

• Install the firestop spacer.

These firestop spacers are designed to provide the

minimum 2 in. (51 mm) air space required around the

chimney. In all situations, the firestop spacers are to be

nailed to the ceiling joists from the bottom or fireplace

side,

EXCEPT when the space above is an insulated

ceiling or attic space. In this situation, the firestop spacer

must be nailed from the top side to prevent loose insula-

tion from falling into the required 2 in. (51 mm) air space

around the chimney.

NOTE: See Figures 24.1 and 24.2 on page 24.

Note: The ceiling firestop MUST be nailed to the bottom

of the ceiling joists EXCEPT when the space above is

uninsulated and the attic insulation shield is not being used

(see Figure 23.2). When the attic insulation shield is used

the ceiling firestop may be above or below the joist of an

insulated ceiling.

Note: You must provide support for the pipe during

construction and check to be sure inadvertent loading has

not dislodged the chimney section from the fireplace or at

any chimney joint.

• Ceiling firestops must be used at ceiling/floor.

• Chase construction requires ceiling firestops at each

floor or every 10 ft (3.05 m) of clear space.

• Use same dimensional lumber as joists.
Ceiling firestop slows spread of fire and reduces cold air

infiltration.

CAUTION

ROOM ABOVE (non-insulated ceiling)

ATTIC ABOVE (insulated ceiling)

B

A

Ceilng firestop

attached to bottom

of framing

Ceiling firestop

attached to top of

framing

When attic insulation

shield not used

Note:

Use same dimensional lumber for framing

ceiling firestop and joists.

2 in. (51mm)

clearance

2 in. (51mm)

clearance

Figure 23.2 Installing the Ceiling Firestop

Catalog #

A

B

in.

mm

in.

mm

FS338

14-1/2

368

14-1/2

368

FS339

14-1/2

368

18-3/8

467

FS340

14-1/2

368

23

584

Wire Ties

Wire Ties

4" Flex

Figure 23.1 Installing Flex Pipe