Caution, Warning – Hearth and Home Technologies C-40 User Manual

Page 16

Advertising
background image

Page 16

Heatilator • Constitution EPA Fireplace • 480-1091C

November 11, 2008

Risk of Smoke Spillage
Outside air inlet must be located to prevent blockage

from:

• Leaves

• Snow/ice

• Other debris
Blockage may cause combustion air starvation.

CAUTION

Fire Risk

Asphyxiation Risk

Do not draw outside combustion air from:

• Wall, floor or ceiling cavity.

• Enclosed space such as an attic or

garage.

• Close proximity to exhaust vents or

chimneys.

Fumes or odor may result.

WARNING

Figure 16.1 Outside Air Inlet Locations

Attic insulation shield

must be used to keep

insulation away from

chimney.

Ceiling firestop

on floor of attic.

3 ft min. from top of

uppermost chimney

section to air inlet.

Figure 16.2 Locating the Outside Air Control

Handle Left - Closed

Handle Right - Open