Heatilator • Constitution EPA Fireplace • 480-1091C

November 11, 2008

G. Install the Attic Insulation Shield

An insulation shield must be installed when there is a pos-

sibility of insulation coming into contact with the factory built

chimney system.
• Bend the tabs at the top of the attic insulation shield inward.

This will help keep the chimney section centered in the

shield.

• Position the shield over the vertical chimney section where

it penetrates a ceiling firestop.

• Slide the shield down until it rests on the ceiling firestop.

The ceiling firestop will support the insulation shield. See

Figures 24.1 and 24.2.

H. Double-check the Chimney Assembly

Continue assembling the chimney sections up through the

ceiling firestops as needed. While doing so, be aware of the

height and unsupported chimney length limitations given un-

der Section 5.A. Chimney Requirements.
Check each section by pulling up slightly from the top to en-

sure proper engagement before installing the succeeding

sections. If they have been connected correctly, they will not

disengage when tested.

I. Secure the Chimney

When offsets and returns are joined to straight pipe sections,

they must be locked into position with the screws provided*

(outer only), using the predrilled holes. To prevent gravity

from pulling the chimney sections apart, the returns and the

chimney stabilizers have hanger straps for securing these

parts to joists or rafters. See Figure 24.3.
* Use #6 or #8 sheet metal screw, or larger, no longer than

1/2 in. (13mm).

Attic Insulation

Shield

Chimney

Insulation

Ceiling Firestop

Tabs

24 in.

(610mm)

10-1/2 in.

(267mm)

14-1/2 in. (368mm)
2 in. (51mm)

Figure 24.1 Install Attic Insulation Shield Above the Ceiling

24 in.

(610 mm)

Attic

Insulation

Shield

Chimney

Insulation

10-1/2 in.

(267 mm)

14-1/2 in. (368 mm)

Ceiling Firestop

Tabs

2 in. (51mm)

Figure 24.2 Install Attic Insulation Shield Below the Ceiling

Ceiling

Firestop

Straps

Optional

Additional

Support

Joint

Band

(Optional)

Figure 24.3 Secure the Chimney

Fire Risk

• Secure offsets with screws (not to exceed

1/2 in. / 13mm in length).

WARNING

• Secure returns with strapping.

• Straight chimney sections may be secured with screws

(not to exceed 1/2 in./13 mm in length) at the joints.

Keep chimney sections from separating or twisting.

Fire Risk

• DO NOT pack insulation or other

combustibles: between ceiling firestops;

between chimney and attic insulation

shield.

WARNING

• ALWAYS maintain specified clearances around chimney

and ceiling firestop systems.

• Install ceiling firestops as specified.
Failure to keep insulation or other material away from

chimney pipe may cause fire.