E. Timer Assembly Replacement

Shock Risk
Disconnect power by turning off circuit breaker

BEFORE servicing.

CAUTION

1. Remove both doors by lifting doors up and off of

hinges.

2. Remove the black knob and spring handle.
3. Remove the outside air knob and then the 4 screws from

each corner of fascia and remove the fascia. Place on

protected surface.

4. Remove the 3 center bricks from back of fireplace and

all the floor bricks

.

5. Remove 2 Phillips head screws and pry open access

door in the bottom of the fireplace with a flat head screw-

driver. Figure 35.2.

Remove 2 screws

in cover plate

Cover Plate

Pry pointed edge

toward fireplace and

then down and out to

remove.

Cover Plate

Remove 2 screws & pry open door

Spring Handle

Black Knob

Linkage Arm

1/4” bolts

Timer Assemby

Cover Plate

Mechanical

Timer

Figure 35.1 Timer Assembly

Figure 35.2

6. Remove 2 screws from cover plate & pull cover plate

toward you. Figures 35.3 & 35.4. Use a flat head screw-

driver to pry the corner edge loose. Pry toward the fire-

place and then press down and out. Figure 35.5.

Figure 35.3

Figure 35.4

Figure 35.5