Warning – Hearth and Home Technologies C-40 User Manual

Page 39

Advertising
background image

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page 39

Figure 39.1 Positioning the Protective Metal Hearth Strips

Fire Risk

• Metal hearth strips MUST be installed.
Sparks or embers may ignite flooring.

WARNING

Fire Risk

• Hearth extensions must be installed

exactly as specified.

High temperatures or hot embers may ignite

concealed combustibles.

WARNING

1in. (25mm) OVERLAP

Metal strips 2 in. (51mm) under edge of

Fireplace and Hearth Extension and 2 in.

(51mm) on both side of fireplace opening.

Nail or screw metal strips in place.

NONCOMBUSTIBLE

DECORATIVE MATERIAL

(2) HX4 MICORE FACTORY

BUILT HEARTH EXTENSION

(Each HX4 = 1/2 in. (13mm) thick)

HEARTH METAL STRIPS

GAP (SEAL WITH NONCOMBUSTIBLE SEALANT)

UP TO BOTTOM OF FASCIA

6 in. (152mm)

1/2 in. (13mm)

1. Fireplace and Hearth Extension are flush on the

floor:

Non-combustible flooring 20 in. (508mm) in front of and 8 in.

(203mm) to either side of the fuel opening with a minimum

thickness of 1 in. (25mm) and (“k” value = 0.49). See Figure

39.2 and 39.3 and Figures 40.1 and 40.2 on page 40.

2. Fireplace is installed flush on the floor and Hearth

Extension is raised to the bottom of the fascia:

Raised hearth must be constructed of non-combustible

materials such as cement block or equivalent material. Non-

combustible flooring on the raised hearth

must be 20 in. (508

mm) in front of and 8 in. (203 mm) to either side of the fuel

opening with a minimum thickness of 1 in. (25 mm) and (“k”

value = 0.49). See Figure 40.3 on page 40.

Figure 39.3 Side View of Factory Built Hearth Extension

Figure 39.2 Hearth Extension Dimensions

B

8 in. (203mm)

from each side of

fuel loading door

A

Model #

Constitution

A

B

in.

41

20

mm

1041

508

The construction of, and materials used for a hearth exten-

sion are shown in Figures 39.2 and 39.3. A hearth extension

of this construction may be covered with any non-combustible

decorative material and may have a maximum thickness as per

Figure 38.1 on page 38. Seal gaps between the hearth exten-

sion and the front of the fireplace with a bead of non-combus-

tible sealant.

Advertising