Troubleshooting

104

0B02

Public Ethernet Set IP Error
(The library could not set the IP

parameters)

•

Make sure a valid Ethernet address has

been programmed using the LCD touch

display. (Menu -> Maintenance ->

Library)

• Reboot the library

1001

SCSI Firmware Error
(Internal SCSI task processing error.

Unexpected state or hardware status.)

•

Turn off power to the library and inspect

connectors and cables.

•

Check the SCSI cable connections to

make sure they are secured.

•

Make sure the library controller board

has SCSI termination.

1002

SCSI FIFO Empty
(The SCSI controller data FIFO is empty

but should contain more data bytes.)

•

Turn off power to the library and inspect

connectors and cables.

•

Check the SCSI cable connections to

make sure they are secured.

•

Make sure the library controller board

has SCSI termination.

1003

SCSI FIFO Error
(The SCSI controller data FIFO should be

empty but still contains data bytes.)

•

Turn off power to the library and inspect

connectors and cables.

•

Check the SCSI cable connections to

make sure they are secured.

•

Make sure the library controller board

has SCSI termination.

1004

SCSI Gross Error
(The SCSI controller detected a gross error

condition. Invalid SCSI bus phase or

DMA error.)

•

Turn off power to the library and inspect

connectors and cables.

•

Ensure SCSI options are set correctly.

•

Check the SCSI cable connections to

make sure they are secured.

•

Make sure the library controller board

has SCSI termination.

•

Check host SCSI cable and connections.

Table 10

Fault Symptom Codes (continued)