MSL6000 series tape library user guide 125

5014

Drive Already Loaded
(Cleaning operation failed because the

drive already has a cartridge inserted.)

•

Press the Enter button to clear the

message.

•

Invalid user initiated operation. Set

parameters correctly and try again.

•

If the tape in the drive is not in use,

unload the drive and retry the cleaning

operation.

5015

Expired Clean'g Cart
(Cleaning operation failed due to an

expired cleaning cartridge.)

•

Press the Enter button to clear the

message.

•

Remove expired cleaning cartridge from

library and discard. Replace with new

cleaning cartridge.

5016

Not a Clean'g Cart
(Cleaning operation failed because the

loaded cartridge is not a cleaning

cartridge.)

•

Press the Enter button to clear the

message.

•

Make sure tape in reserved slot is a

cleaning cartridge.

•

Invalid user initiated operation. Set

parameters correctly and try again.

5035

Drive Timeout Error
(Cleaning operation failed because the

drive timed out.)

•

Press the Enter button to clear the

message.

•

Invalid user initiated operation. Set

parameters correctly and try again.

•

Ensure the drive shows good status

through the drive status window.

503B

Move Command Fail
(A front panel move operation failed.)

•

Press the Enter button to clear the

message.

•

Invalid user initiated operation. Set

parameters correctly and try again.

503C Clean Operation Timeout

(Cleaning operation failed because the

drive timed out.)

•

Press the Enter button to clear the

message.

•

Invalid user initiated operation. Set

parameters correctly and try again.

•

Ensure the drive shows good status

through the drive status window.

Table 10

Fault Symptom Codes (continued)

FSC

Message

ERP