Troubleshooting

112

3019

Drive Open Door Failed

Press the Enter button to reboot.

Ensure the drive shows good status

through the drive status window.

Deactivate the drive using the GUI control

panel maintenance menu.

Reseat the drive.

Load/unload a cartridge to the drive to

verify.

Check the tape cartridge used int he last

operation for damage.

Run the cartridge cycle diagnostic to

verify.

301A Drive Close Door Failed

Press the Enter button to reboot.

Ensure the drive shows good status

through the drive status window.

Deactivate the drive using the GUI control

panel maintenance menu.

Reseat the drive.

Load/unload a cartridge to the drive to

verify.

Check the tape cartridge used in the last

operation for damage.

Run the cartridge cycle diagnostic to

verify.

301B

Drive Communication Error
(Intertask send, receive failed.)

Press the Enter button to reboot.

Ensure the drive shows good status

through the drive status window.

Deactivate the drive using the GUI control

panel maintenance menu.

Reseat the drive.

Check cabling.

Load/unload a cartridge to the drive to

verify.

Check the tape cartridge used in the last

operation for damage.

Run the cartridge cycle diagnostic to

verify.

Table 10

Fault Symptom Codes (continued)

FSC

Message

ERP