Troubleshooting

112

3019

Drive Open Door Failed

•

Press the Enter button to reboot.

•

Ensure the drive shows good status

through the drive status window.

•

Deactivate the drive using the GUI control

panel maintenance menu.

•

Reseat the drive.

•

Load/unload a cartridge to the drive to

verify.

•

Check the tape cartridge used int he last

operation for damage.

•

Run the cartridge cycle diagnostic to

verify.

301A Drive Close Door Failed

•

Press the Enter button to reboot.

•

Ensure the drive shows good status

through the drive status window.

•

Deactivate the drive using the GUI control

panel maintenance menu.

•

Reseat the drive.

•

Load/unload a cartridge to the drive to

verify.

•

Check the tape cartridge used in the last

operation for damage.

•

Run the cartridge cycle diagnostic to

verify.

301B

Drive Communication Error
(Intertask send, receive failed.)

•

Press the Enter button to reboot.

•

Ensure the drive shows good status

through the drive status window.

•

Deactivate the drive using the GUI control

panel maintenance menu.

•

Reseat the drive.

•

Check cabling.

•

Load/unload a cartridge to the drive to

verify.

•

Check the tape cartridge used in the last

operation for damage.

•

Run the cartridge cycle diagnostic to

verify.

Table 10

Fault Symptom Codes (continued)

FSC

Message

ERP