Init Element Status

Lets you specify the library’s response to the SCSI
INITIALIZE ELEMENT STATUS

command. The

possible settings are No Inventory, Force Inventory, and

Force Label Scan. The default is Force Inventory.

Test Unit Ready

Reporting

Lets you specify the response to a TEST UNIT READY

command if the library is in Sequential Mode. The

possible settings are Standard or Custom. The default is

Custom.

Device Capability Page

Length

Lets you choose between two lengths of the mode

sense/select device capabilities page (SCSI page 1Fh),

which are Short (14 bytes) and Long (18 bytes), to

accommodate different SCSI device implementations of

this page. The default is Short (14 bytes).

Transport Element

Base Address

Lets you set the base address for the robotics mechanism.

The default is 0x0.

Storage Element

Base Address

Lets you set the base address for the magazine slots. The

default is 0x20.

Transfer Element

Base Address

Lets you set the base address for the tape drives. The

default is 0x1E0.

Import/Export Element

Base Address

Lets you set the base address for the mail slot. The default

is 0x1C0.

Product Identification

(PID)

Lets you specify the response of the library’s robotics to the
SCSI INQUIRY

command in the Product Identification

field. The default is MSL6000 Series.

Vendor Identification

(VID)

Lets you specify the response of the library’s robotics to the
SCSI INQUIRY

command in the Vendor Identification

field. The default is HP.

Post Recovered Errors

Lets you specify whether or not recovered errors are

posted. The default is Disabled.

Table 6

View SCSI Options (continued)