HP MSL6000 Series User Manual

Page 111

Advertising
background image

MSL6000 series tape library user guide 111

3016

Drive Status Failure

Press the Enter button to reboot.

Ensure the drive shows good status

through the drive status window.

Deactivate the drive using the GUI control

panel maintenance menu.

Reseat the drive.

Check cabling.

Load/unload a cartridge to the drive to

verify.

Check the tape cartridge used in the last

operation for damage.

Run the cartridge cycle diagnostic to

verify.

3017

Drive In Flux Timeout
(Time-out waiting for drive to clear the full

status.)

Press the Enter button to reboot.

Ensure the drive shows good status

through the drive status window.

Deactivate the drive using the GUI control

panel maintenance menu.

Reseat the drive.

Check cabling.

Load/unload a cartridge to the drive to

verify.

Run the cartridge cycle diagnostic to

verify.

3018

Drive Load Retry Failed
(SLTO drive fail to load, detected in drive

task.)

Press the Enter button to reboot.

Ensure the drive shows good status

through the drive status window.

Deactivate the drive using the GUI control

panel maintenance menu.

Reseat the drive.

Check cabling.

Load/unload a cartridge to the drive to

verify.

Check the tape cartridge used int he last

operation for damage.

Run the cartridge cycle diagnostic to

verify.

Table 10

Fault Symptom Codes (continued)

FSC

Message

ERP