Troubleshooting

126

503D

Drive Status Fail
(Cleaning operation failed because the

library could not retrieve drive status.)

Press the Enter button to clear the

message.

Invalid user initiated operation. Set

parameters correctly and try again.

Ensure the drive shows good status

through the drive status window.

6001

Inter-Module Unknown Event
(Inter-module communication failure.)

Press Enter to reboot.

• Check pass-through connections.
• Check network connections to the

network router.

6002

Inter-Module no command matching

response

Verify operation and retry.

• Update the Map using the LCD touch

display. (Menu -> Maintenance -> Force

reconfiguration)

6003

Inter-Module command length
(Incorrect command length.)

Verify operation and retry.

• Update the Map using the LCD touch

display. (Menu -> Maintenance -> Force

reconfiguration)

6004

Inter-Module loopback buffer mismatch

Cycle power to the library or reboot by

using the LCD touch display.

• Retry operation.

6005

Inter-Module bad data length
(Incorrect data length.)

Verify operation and retry.

• Update the Map using the LCD touch

display. (Menu -> Maintenance -> Force

reconfiguration)

6006

Inter-Module bad packet length
(Incorrect packet length.)

Verify operation and retry.

• Update the Map using the LCD touch

display. (Menu -> Maintenance -> Force

reconfiguration)

6007

Inter-Module failed to allocate TCP buffer

Power cycle the library.

• Check pass-through connections.

6008

Inter-Module pending table full

Power cycle the library.

• Retry the operation.

7001

Command response from unexpected

source

Press the Enter button to reboot.

Cycle power to the library or reboot

using the GUI touch screen.

Table 10

Fault Symptom Codes (continued)

FSC

Message

ERP

Advertising