Troubleshooting

116

305B

Diag Fetch, Drive not loaded
(Diag: no cartridge present for fetch.)

Press the Enter button to clear the

message.

Load a cartridge in the drive and retry

the operation.

Invalid user initiated operation. Set

parameters correctly and try again.

305D Diag Timeout waiting for drive empty,

ready
(Fetch, time-out waiting for drive unload.)

Press the Enter button to reboot.

Invalid user initiated operation. Set

parameters correctly and try again.

Ensure the drive shows good status

through the drive status window.

Check the tape cartridge used in the last

operation for damage.

305F

Invalid bin number
(Invalid bin number detected in diag.)

Press the Enter button to clear the

message.

Invalid user initiated operation. Set

parameters correctly and try again.

3060

Zone Sequence Error
(Robot did not find sensor on power-up.)

Cycle power to the library or reboot

using the GUI touch screen.

3074

Drive 0 Eject Failed
(Eject command time-out.)

Press the Enter button to reboot.

Ensure the drive shows good status

through the drive status window.

Deactivate the drive using the GUI control

panel maintenance menu.

Reseat drive.

Load/unload a cartridge to the drive to

verify.

Check the tape cartridge used in the last

operation for damage.

Run the cartridge cycle diagnostic to

verify.