HP MSL6000 Series User Manual

Page 130

Advertising
background image

Troubleshooting

130

701B

Invalid L-drive number to convert
(Attempted to send a command to a

drive, but the logical drive number is out

of range.)

•

Press the Enter button clear the

message.

•

Cycle power to the library or reboot

using the GUI touch screen.

•

Ensure the drive shows good status

through the drive status window.

701C Invalid P-drive number to convert

(Attempted to send a command to a

drive, but the physical drive number is out

of range.)

•

Press the Enter button clear the

message.

•

Cycle power to the library.

•

Ensure the drive shows good status

through the drive status window.

701D

Invalid mod number to convert
(Attempted to send a command to a drive

in a remote module, but the module

number is out of range.)

•

Press the Enter button clear the

message.

•

Cycle power to the library or reboot

using the GUI touch screen.

701E

Unknown drive type
(Attempted to show detailed drive status

of a drive whose type is unknown.)

•

Press the Enter button clear the

message.

•

Cycle power to the library or reboot

using the GUI touch screen.

•

Ensure the drive shows good status

through the drive status window.

701F

The SCSI response was not expected
(The command response from the SCSI

task in a remote module was

unexpected.)

•

Press the Enter button clear the

message.

•

Cycle power to the library or reboot

using the GUI touch screen.

•

Ensure the drive shows good status

through the drive status window.

7020

The Flash response was not expected
(The command response from the Flash

task in a remote module was

unexpected.)

•

Press the Enter button clear the

message.

•

Cycle power to the library or reboot

using the GUI touch screen.

•

Ensure the drive shows good status

through the drive status window.

Table 10

Fault Symptom Codes (continued)

FSC

Message

ERP