Troubleshooting

130

701B

Invalid L-drive number to convert
(Attempted to send a command to a

drive, but the logical drive number is out

of range.)

Press the Enter button clear the

message.

Cycle power to the library or reboot

using the GUI touch screen.

Ensure the drive shows good status

through the drive status window.

701C Invalid P-drive number to convert

(Attempted to send a command to a

drive, but the physical drive number is out

of range.)

Press the Enter button clear the

message.

Cycle power to the library.

Ensure the drive shows good status

through the drive status window.

701D

Invalid mod number to convert
(Attempted to send a command to a drive

in a remote module, but the module

number is out of range.)

Press the Enter button clear the

message.

Cycle power to the library or reboot

using the GUI touch screen.

701E

Unknown drive type
(Attempted to show detailed drive status

of a drive whose type is unknown.)

Press the Enter button clear the

message.

Cycle power to the library or reboot

using the GUI touch screen.

Ensure the drive shows good status

through the drive status window.

701F

The SCSI response was not expected
(The command response from the SCSI

task in a remote module was

unexpected.)

Press the Enter button clear the

message.

Cycle power to the library or reboot

using the GUI touch screen.

Ensure the drive shows good status

through the drive status window.

7020

The Flash response was not expected
(The command response from the Flash

task in a remote module was

unexpected.)

Press the Enter button clear the

message.

Cycle power to the library or reboot

using the GUI touch screen.

Ensure the drive shows good status

through the drive status window.

Table 10