Troubleshooting

108

2092

Open Right Door Fault
(Door open sensor time-out detected

when open door.)

Press the Enter button to clear the

message.

Cycle power to the library or reboot

using the GUI touch screen.

Run sensor test.

Make sure door(s) are closed.

2093

Open Doors Fault
(Door open sensor time-out detected

when open door.)

Press the Enter button to clear the

message.

Cycle power to the library or reboot

using the GUI touch screen.

Run sensor test.

Make sure door(s) are closed.

2094

Open DLT Handle Fault
(Failed to open DLT handle.)

Press Enter to clear the message.

• Cycle power to the library or reboot by

using the LCD touch display

• Make sure the drive shows good status

through the drive status window.

20a0

No IP Address Found
(SMC router failed to get an IP address.)

Press the Enter button to clear the

message.

Ensure network configuration options are

set correctly.

Cycle power to the library or reboot

using the GUI touch screen.

20a1

No IP Address Mode Fault
(SMC router failed to detect static or IP

address mode.)

Press the Enter button to clear the

message.

Ensure network configuration options are

set correctly.

Cycle power to the library or reboot

using the GUI touch screen.

20b0

Unknown Exchange For The Async

message
(Unexpected exchange detected when

process messages.)

Press the Enter button to reboot.

Cycle power to the library or reboot

using the GUI touch screen. Wait 30

seconds to power up again.

Table 10

Fault Symptom Codes (continued)

FSC

Message

ERP