HP MSL6000 Series User Manual

Page 123

Advertising
background image

MSL6000 series tape library user guide 123

3110

Picker Retries Exceeded

Cycle power to the library or reboot by

using the LCD touch display.

• Run cartridge cycle test using the LCD

touch display. (Menu -> Maintenance ->

Diagnostic options)

Note: If the backup application is running,

update the application cartridge map.

3111

Picker Retries Exceeded 1
(Picker retries exceeded during a

pass-through fetch operation.)

Press the Enter button to reboot.

Cycle power to the library or reboot

using the GUI touch screen.

Check pass-through alignment.

3112

Picker Retries Exceeded 2

Cycle power to the library or reboot by

using the LCD touch display.

• Run cartridge cycle test using the LCD

touch display. (Menu -> Maintenance ->

Diagnostic options)

Note: If the backup application is running,

update the application cartridge map.

3113

Picker Retries Exceeded 3
(Picker retries exceeded during a bin stow

operation.)

Press the Enter button to reboot.

Cycle power to the library or reboot

using the GUI touch screen.

Ensure that there are no obstructions

inside the library (all cartridges are in

magazines).

Ensure cartridges are fully inserted in the

magazine(s).

3115

Picker Retraction Error
(Picker did not retract during a bin check

operation.)

Press the Enter button to reboot.

Cycle power to the library or reboot

using the GUI touch screen.

3200

Shuttle Jammed
(Shuttle could not reach target location.)

Press the Enter button to reboot.

Check pass-through mechanism

alignment.

Cycle power to the library or reboot

using the GUI touch screen.

Table 10

Fault Symptom Codes (continued)

FSC

Message

ERP

Advertising
This manual is related to the following products: