Hitachi SJ700-2 Series User Manual

Page 10

Advertising
background image

1 - 6

Default

Code

Function name

Monitored data or setting

_FF

_FEF

_FUF

Note

A081

AVR function select

00 (always on), 01 (always off), 02 (off during deceleration)

02

00

00

AV

R

A082

AVR voltage select

200 V class: 200, 215, 220, 230, 240 (V)
400 V class: 380, 400, 415, 440, 460, 480 (V)

200/400 230/400 230/460

A085

Operation mode selection

00 (normal operation), 01 (energy-saving operation), 02 (fuzzy operation) 00

A086

Energy saving mode tuning

0.1 to 100.0

50.0

A092

Acceleration (2) time setting

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

15.00

A292

Acceleration (2) time setting,
2nd motor

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

15.00

A392

Acceleration (2) time setting,
3rd motor

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

15.00

A093

Deceleration (2) time setting

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

15.00

A293

Deceleration (2) time setting,
2nd motor

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

15.00

A393

Deceleration (2) time setting,
3rd motor

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

15.00

A094

Select method to switch to
Acc2/Dec2 profile

00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only
when rotation is reversed)

00

A294

Select method to switch to
Acc2/Dec2, 2nd motor

00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only
when rotation is reversed)

00

A095

Acc1 to Acc2 frequency
transition point

0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

A295

Acc1 to Acc2 frequency
transition point, 2nd motor

0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

A096

Dec1 to Dec2 frequency
transition point

0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

A296

Dec1 to Dec2 frequency
transition point, 2nd motor

0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

A097

Acceleration curve selection

00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)

00

O

per

at

ion

m

ode and

acc

eler

at

ion/

deceler

at

ion

fu

nct

ion

A098

Deceleration curve setting

00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)

00

A101

[OI]-[L] input active range start
frequency

0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

A102

[OI]-[L] input active range end
frequency

0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

A103

[OI]-[L] input active range start
current

0. to "[OI]-[L] input active range end current" (%)

20.

A104

[OI]-[L] input active range end
current

"[OI]-[L] input active range start current" to 100. (%)

100.

A105

[OI]-[L] input start frequency
enable

00 (external start frequency), 01 (0 Hz)

00

A111

[O2]-[L] input active range start
frequency

-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

A112

[O2]-[L] input active range end
frequency

-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

A113

[O2]-[L] input active range start
voltage

-100. to 02 end-frequency rate (%)

-100.

Ext

er

nal f

requen

cy

adjus

tm

en

t

A114

[O2]-[L] input active range end
voltage

"02 start-frequency rate" to 100. (%)

100.

A131

Acceleration curve constants
setting

01 (smallest swelling) to 10 (largest swelling)

02

n and

deceler

at

io

A132

Deceleration curve constants
setting

01 (smallest swelling) to 10 (largest swelling)

02

A141

Operation-target frequency
selection 1

00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via
OI), 04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string
frequency input)

02

A142

Operation-target frequency
selection 2

00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via
OI), 04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string
frequency input)

03

A143 Operator

selection

00 (addition: A141 + A142), 01 (subtraction: A141 - A142), 02 (multiplication:
A141 x A142)

00

A145

Frequency to be added

0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

O

per

at

ion-

tar

ge

t f

requen

cy

A146

Sign of the frequency to be
added

00 (frequency command + A145), 01 (frequency command - A145)

00

A150

EL-S-curve acceleration
ratio 1

0. to 50. (%)

25.

A151

EL-S-curve acceleration
ratio 2

0. to 50. (%)

25.

A152

EL-S-curve deceleration
ratio 1

0. to 50. (%)

25.

Acceler

at

ion and

deceler

at

ion

A153

EL-S-curve deceleration
ratio 2

0. to 50. (%)

25.

Advertising