4 warning codes – Hitachi SJ700-2 Series User Manual

Page 38

Advertising
background image

2- 10

2.4 Warning Codes

The following table lists the warning codes and the contents of parameter readjustments:

Warning code

Target function code

Condition

Basic function code

001/ 201

Frequency upper limit setting (A061/A261)

>

002/ 202

Frequency lower limit setting (A062/A262)

>

004/ 204/ 304 Base frequency setting (A003/A203/A303) (*1)

>

005/ 205/ 305

Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)

>

006/ 206/ 306 Multispeed 1 to 15 settings (A021 to A035)

>

009

Home search speed setting (P015)

>

Maximum frequency setting
(A004/A204/A304)

012/ 212

Fequency lower limit setting (A062/A262)

>

015/ 215

Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)

>

016/ 216

Multispeed 1 to 15 settings (A021 to A035)

>

Frequency upper limit setting
(A061/A261)

019

<

Home search speed setting
(P015)

021/ 221

Frequency upper limit setting (A061/A261)

<

025/ 225

Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)

<

Fequency lower limit setting
(A062/A262)

031/ 231

Frequency upper limit setting (A061/A261)

<

032/ 232

Fequency lower limit setting (A062/A262)

<

035/ 235/ 335 Output frequency setting (F001), multispeed 0

(A202/A220/A320) (*2)

<

036

Multispeed 1 to 15 settings (A021 to A035)

<

037

Jog frequency setting (A038)

<

Start frequency adjustment (b082)

085/ 285/ 385

Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)

<>

086

Multispeed 1 to 15 settings (A021 to A035)

<>

Jump (center) frequency settings
1/2/3 ± " Jump (hysteresis)
frequency width settings 1/2/3"
A063 ± A064, A065 ± A066,
A067 ± A068 (*3)

091/ 291

Frequency upper limit setting (A061/A261)

>

092/ 292

Fequency lower limit setting (A062/A262)

>

095/ 295

Output frequency setting (F001), multispeed 0
(A202/A220/A320) (*2)

>

096

Multispeed 1 to 15 settings (A021 to A035)

>

Free-setting V/f frequency (1) to (6) (b100, b102, b104, b106,
b108, b110)

>

Free-setting V/f frequency (7)
(b112)

Free-setting V/f frequency (2) to (6) (b102, b104, b106, b108,
b110)

<

Free-setting V/f frequency (1)
(b100)

Free-setting V/f frequency (1) (b100)

>

Free-setting V/f frequency (3) to (6) (b104, b106, b108, b110)

<

Free-setting V/f frequency (2)
(b102)

Free-setting V/f frequency (1) (2) (b100, b102)

>

Free-setting V/f frequency (4) to (6) (b106, b108, b110)

<

Free-setting V/f frequency (3)
(b104)

Free-setting V/f frequency (1) to (3) (b100, b102, b104, b110)

>

Free-setting V/f frequency (5) (6) (b108, b110)

<

Free-setting V/f frequency (4)
(b106)

Free-setting V/f frequency (1) to (4) (b100, b102, b104, b106)

>

Free-setting V/f frequency (6) (b110)

<

Free-setting V/f frequency (5)
(b108)

110

Free-setting V/f frequency (1) to (5) (b100, b102, b104, b106,
b108)

>

Free-setting V/f frequency (6)
(b110)

Free setting, electronic thermal frequency (2) (3) (b017/b019)

<

Free setting, electronic thermal
frequency (1) (b015)

Free setting, electronic thermal frequency (1) (b015)

>

Free setting, electronic thermal frequency (3) (b019)

<

Free setting, electronic thermal
frequency (2) (b017)

120

Free setting, electronic thermal frequency (1) (2) (b015/b017)

>

Free setting, electronic thermal
frequency (3) (b019)

The inverter displays a warning code when the data set as a target function code satisfies the condition (specified in
the Condition column) in relation to the data set as the corresponding basic function code.
Each parameter (target function code) is readjusted to the data set as the basic function code (by updating at the
inverter start-up).
*1 In this case, the base frequency is rewritten at parameter readjustment. If the base frequency is updated to an

inappropriate value, a motor burnout may result. Therefore, if the warning is displayed, change the current base
frequency data to an appropriate value.

*2 These parameters are checked, even when the digital operator (02) is not specified for the frequency source

setting (A001).

*3 The current value of the jump (center) frequency is updated to "'the current value of the jump frequency' - 'value of