Hitachi SJ700-2 Series User Manual

Page 45

Advertising
background image

4-1

4.The check of control power supply voltage and a control signal
4.1 Control power supply

Measurement place

Item

Tolerance level

+ -

PV5 +5V power supply

4.5-5.5V

J1 connector 5pin,6pin

Control terminal L

PV12 +12V power supply

10.8V-13.2V

J1 connector 3pin

Control terminal L

Nv12 -12V power supply

-13.2V--10.8V

J1 connector 4pin

Control terminal L

PV24 +24V power supply

21.6V-26.4V

J1 connector 2pin,3pin

Control terminal P24

Control terminal CM1

4.2 Control signal

Signal Measurement

place

The

controls of operation

Observation waveform

VDC

J1 connector 32pin-L

A main circuit direct-current voltage detected
signal
VDC=6.396V/400V*VPN(200Vclass)
VDC=6.396V/800V*VPN(400Vclass)

Direct-current voltage

IUF

IWF

J1 connector 31pin-L
J1 connector 30pin-L

A motor current detected signal
At the time of inverter rated load:About 3.3V
peak.

TRIP

J1 connector 17pin-L

The signal at the time of carrying out a trip by the
trip factor which a gate array judges (P3-1
reference)

Direct-current voltage

PHF

J1 connector 37pin-L

Phase failure protection detected signal
Normal:5V(H)
Phase failure detection :about 0.5V(L)

Direct-current voltage

IPL

J1 connector 33pin-L

The instantaneous power failure signal of R0-T0
part.
Power On :about 0.5V(L)
Power Off : 5V(H)

Direct-current voltage

GS

J1 connector 36pin-L

Power-module protection
Under operation :about 5V(H)
Under a stop :about 0.5V(L)

Direct-current voltage

US
VS

WS

J1 connector 15pin-L
J1 connector 35pin-L
J1 connector 36pin-L

PWM signal
Upper arm ON :about 3.5V(L)
Lower arm ON :about 5V(H)

TRES J1 connector 40pin-L



The trip distinguished by GA is canceled.
Normal :about 5V(H)
Under reset :about 0.5V(L)

0V

3.3V

3.3V

0

5

3.5

Upper arm

ON

Lower arm

ON

0

5

0.5

Reset

Reset

Advertising