Hitachi SJ700-2 Series User Manual

Page 34

Advertising
background image

2- 6

2.2.2 Error indications by protective functions with the digital option board (SJ-DG)
mounted

Name Description

Display on digital

operator

Display on

remote operator

ERR1***

SJ-DG error

If timeout occurs during the communication
between the inverter and digital option board, the
inverter will shut off its output and display the error
code shown on the right.

OP1-0

OP2-0

Note: The input mode is determined by a combination of DI switch and rotary switch settings. If the option

board does not operate normally, confirm the DIP switch and rotary switch settings on the option
board.


Functions of the DIP and rotary switches on the digital option board (SJ-DG)

DIP switch

Rotary

switch

Frequency setting

Acceleration/

deceleration time setting

Torque limit

setting

Position

setting

Type Code

Data

resolution

Switch No.

1 2

Code for

setting

0.01 Hz

0.1 Hz

1 Hz

Rate

0.01 sec 0.1 sec

1 sec

1% 1

pulse

0

1

2

3

4

5

OFF: PAC

(batch

input

mode)

6

0

1

2

3

4

5

6

7

8

9

A

OFF: BIN

(binary

input)/

ON: BCD

(BCD
input)

ON: DIV

(divided-inp

ut mode)

B

: Input mode specified by switch settings

Note: For details, refer to the instruction manual for the option board.