Hitachi SJ700-2 Series User Manual

Page 17

Advertising
background image

1 - 13

Default

Code

Function name

Monitored data or setting

_FF _FEF

_FUF

Note

Te

rm

inal

C111

Overload setting (2)

0.0 to 2.00 x "rated current" (A)

Rated current of

inverter

C121

[O] input zero calibration

0. to 9999., 1000 to 6553 (10000 to 65530)

Factory setting

C122

[OI] input zero calibration

0. to 9999., 1000 to 6553 (10000 to 65530)

Factory setting

Adjust

m

ent

C123

[O2] input zero calibration

0. to 9999., 1000 to 6553 (10000 to 65530)

Factory setting

C130

Output 11 on-delay time

0.0 to 100.0 (s)

0.0

C131

Output 11 off-delay time

0.0 to 100.0 (s)

0.0

C132

Output 12 on-delay time

0.0 to 100.0 (s)

0.0

C133

Output 12 off-delay time

0.0 to 100.0 (s)

0.0

C134

Output 13 on-delay time

0.0 to 100.0 (s)

0.0

C135

Output 13 off-delay time

0.0 to 100.0 (s)

0.0

C136

Output 14 on-delay time

0.0 to 100.0 (s)

0.0

C137

Output 14 off-delay time

0.0 to 100.0 (s)

0.0

C138

Output 15 on-delay time

0.0 to 100.0 (s)

0.0

C139

Output 15 off-delay time

0.0 to 100.0 (s)

0.0

C140

Output RY on-delay time

0.0 to 100.0 (s)

0.0

C141

Output RY off-delay time

0.0 to 100.0 (s)

0.0

C142

Logical output signal 1 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C143

Logical output signal 1 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C144

Logical output signal 1 operator
selection

00 (AND), 01 (OR), 02 (XOR)

00

C145

Logical output signal 2 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C146

Logical output signal 2 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C147

Logical output signal 2 operator
selection

00 (AND), 01 (OR), 02 (XOR)

00

C148

Logical output signal 3 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C149

Logical output signal 3 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C150

Logical output signal 3 operator
selection

00 (AND), 01 (OR), 02 (XOR)

00

C151

Logical output signal 4 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C152

Logical output signal 4 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C153

Logical output signal 4 operator
selection

00 (AND), 01 (OR), 02 (XOR)

00

C154

Logical output signal 5 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C155

Logical output signal 5 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C156

Logical output signal 5 operator
selection

00 (AND), 01 (OR), 02 (XOR)

00

C157

Logical output signal 6 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

C158

Logical output signal 6 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

00

O

ut

pu

t t

er

m

inal oper

at

io

n f

unc

tion

C159

Logical output signal 6 operator
selection

00 (AND), 01 (OR), 02 (XOR)

00

C160

Input terminal response time
setting 1

0. to 200. ( ¯2ms) 1

C161

Input terminal response time
setting 2

0. to 200. ( ¯2ms) 1

C162

Input terminal response time
setting 3

0. to 200. ( ¯2ms) 1

C163

Input terminal response time
setting 4

0. to 200. ( ¯2ms) 1

C164

Input terminal response time
setting 5

0. to 200. ( ¯2ms) 1

C165

Input terminal response time
setting 6

0. to 200. ( ¯2ms) 1

C166

Input terminal response time
setting 7

0. to 200. ( ¯2ms) 1

C167

Input terminal response time
setting 8

0. to 200. ( ¯2ms) 1

Input t

er

m

inal

re

sponse

C168

Input terminal response time
setting FW

0. to 200. ( ¯2ms) 1

Oth

er

C169

Multistage speed/position
determination time

0. to 200. ( ¯10ms) 0