Default

Code

Function name

Monitored data or setting

_FF _FEF

_FUF

Note

P001

Operation mode on expansion card
1 error

00 (tripping), 01 (continuing operation)

00

P002

Operation mode on expansion card
2 error

00 (tripping), 01 (continuing operation)

00

P011

Encoder pulse-per-revolution
(PPR) setting

128. to 9999., 1000 to 6553(10000 to 65535) (pulses)

1024.

P012

Control pulse setting

00 (ASR), 01 (APR), 02 (APR2), 03 (HAPR)

00

P013

Pulse train mode setting

00 (mode 0), 01 (mode 1), 02 (mode 2)

00

P014

Home search stop position setting

0. to 4095.

0.

P015

Home search speed setting

"start frequency" to "maximum frequency" (up to 120.0) (Hz)

5.00

P016

Home search direction setting

00 (forward), 01 (reverse)

00

P017

Home search completion range
setting

0. to 9999., 1000 (10000) (pulses)

5.

P018

Home search completion delay
time setting

0.00 to 9.99 (s)

0.00

P019

Electronic gear set position
selection

00 (feedback side), 01 (commanding side)

00

P020

Electronic gear ratio numerator
setting

0. to 9999.

1.

P021

Electronic gear ratio denominator
setting

0. to 9999.

1.

P022

Feed-forward gain setting

0.00 to 99.99, 100.0 to 655.3

0.00

P023

Position loop gain setting

0.00 to 99.99, 100.0

0.50

P024

Position bias setting

-204 (-2048.) / -999. to 2048.

0.

P025

Temperature compensation
thermistor enable

00 (no compensation), 01 (compensation)

00

P026

Over-speed error detection level
setting

0.0 to 150.0 (%)

135.0

P027

Speed deviation error detection
level setting

0.00 to 99.99, 100.0 to120.0 (Hz)

7.50

P028

Numerator of motor gear ratio

0. to 9999.

1.

P029

Denominator of motor gear ratio

0. to 9999.

1.

P031

Accel/decel time input selection

00 (digital operator), 01 (option 1), 02 (option 2), 03 (easy sequence)

00

P032

Positioning command input
selection

00 (digital operator), 01 (option 1), 02 (option 2)

00

P033

Torque command input selection

00 (O terminal), 01 (OI terminal), 02 (O2 terminal), 03 (digital operator)

00

P034

Torque command setting

0. to 200. (%)

0.

P035

Polarity selection at the torque
command input via O2 terminal

00 (as indicated by the sign), 01 (depending on the operation direction)

00

P036

Torque bias mode

00 (disabling the mode), 01 (digital operator), 02 (input via O2 terminal)

00

P037

Torque bias value

-200. to +200. (%)

0.

P038

Torque bias polarity selection

00 (as indicated by the sign), 01 (depending on the operation direction)

00

P039

Speed limit for torque-controlled
operation (forward rotation)

0.00 to "maximum frequency" (Hz)

0.00

P040

Speed limit for torque-controlled
operation (reverse rotation)

0.00 to "maximum frequency" (Hz)

0.00

P044

DeviceNet comm watchdog timer

0.00 to 99.99 (s)

1.00

P045

Inverter action on DeviceNet comm
error

00 (tripping), 01 (tripping after decelerating and stopping the motor), 02
(ignoring errors), 03 (stopping the motor after free-running), 04
(decelerating and stopping the motor)

01

P046

DeviceNet polled I/O: Output
instance number

20, 21, 100

21

P047

DeviceNet polled I/O: Input
instance number

70, 71, 101

71

P048

Inverter action on DeviceNet idle
mode

00 (tripping), 01 (tripping after decelerating and stopping the motor), 02
(ignoring errors), 03 (stopping the motor after free-running), 04
(decelerating and stopping the motor)

01

P049

DeviceNet motor poles setting for
RPM

0, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38
(poles)

0

P055

Pulse-string frequency scale

1.0 to 50.0 (kHz)

25.0

P056

Time constant of pulse-string
frequency filter

0.01 to 2.00 (s)

0.10

P057

Pulse-string frequency bias

-100. to +100. (%)

0.

O

pt

ional f

unct

ions

P058

Pulse-string frequency limit

0. to 100. (%)

100.

Advertising