Parameters – MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 137

Advertising
background image

5 - 14

5. PARAMETERS

Class No. Symbol

Name and function

Initial
value

Unit

Setting

range

Control

mode

21

*OP3 Function selection 3 (Command pulse selection)

Used to select the input form of the pulse train input signal.
(Refer to section 3.4.1)

Command pulse train input form
0: Forward/reverse rotation pulse train
1: Signed pulse train
2: A B-phase pulse train

Pulse train logic selection
0: Positive logic
1: Negative logic

0 0

0000

Refer to
Name
and
function
column.

P

22

*OP4

0000

P S

E

xpa

n

si

on

pa

ra

m

et

ers

1

Function selection 4

Used to select stop processing at forward rotation stroke end (LSP)
reverse rotation stroke end (LSN) off and choose VC/VLA voltage
averaging.

How to make a stop when forward
rotation stroke end (LSP) reverse rotation stroke end
(LSN) is valid. (Refer to section 5.2.3)
0: Sudden stop
1: Slow stop

VC/VLA voltage averaging
Used to set the filtering time when the analog speed
command (VC) voltage or analog speed limit (VLA) is
imported.
Set 0 to vary the speed to voltage fluctuation in real
time. Increase the set value to vary the speed slower
to voltage fluctuation.

Set

value

0

Filtering time [ms]

0

1

0.444

2

0.888

3

1.777

4

3.555

0

0

Refer to
Name
and
function
column.

P S T