CAUTION

Do not install or operate the servo amplifier and servo motor which has been damaged or has any parts

missing.

Provide adequate protection to prevent screws and other conductive matter, oil and other combustible

matter from entering the servo amplifier and servo motor.

Do not drop or strike servo amplifier or servo motor. Isolate from all impact loads.
Securely attach the servo motor to the machine. If attach insecurely, the servo motor may come off during

operation.

The servo motor with reduction gear must be installed in the specified direction to prevent oil leakage.
Take safety measures, e.g. provide covers, to prevent accidental access to the rotating parts of the servo

motor during operation.

Never hit the servo motor or shaft, especially when coupling the servo motor to the machine. The encoder

may become faulty.

Do not subject the servo motor shaft to more than the permissible load. Otherwise, the shaft may break.
When the equipment has been stored for an extended period of time, consult Mitsubishi.

(2) Wiring

CAUTION

Wire the equipment correctly and securely. Otherwise, the servo motor may operate unexpectedly.
Do not install a power capacitor, surge absorber or radio noise filter (FR-BIF option) between the servo

motor and servo amplifier.

Connect the wires to the correct phase terminals (U, V, W) of the servo amplifier and servo motor.

Otherwise, the servo motor does not operate properly.

Connect the servo motor power terminal (U, V, W) to the servo motor power input terminal (U, V, W)

directly. Do not let a magnetic contactor, etc. intervene.

U

Servo motor

M

V

W

U

V

W

U

M

V

W

U

V

W

Servo amplifier

Servo motor

Servo amplifier

Do not connect AC power directly to the servo motor. Otherwise, a fault may occur.
The surge absorbing diode installed on the DC output signal relay of the servo amplifier must be wired in

the specified direction. Otherwise, the emergency stop (EMG) and other protective circuits may not
operate.

COM

(24VDC)

RA

Control

output

signal

Servo amplifier

RA

COM

(24VDC)

Control

output

signal

Servo amplifier

When the cable is not tightened enough to the terminal block (connector), the cable or terminal block

(connector) may generate heat because of the poor contact. Be sure to tighten the cable with specified
torque.