15 - 48

15. ABSOLUTE POSITION DETECTION SYSTEM

(e) Electromagnetic brake output

During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo
motor must be at a stop.
Set "1 1 " in parameter No. 1 of the servo amplifier to choose the electromagnetic brake interlock
(MBR).

Y1

X1

Y4

Electromagnetic brake output

ABS transfer
mode

Brake (MBR)

(f) Positioning completion

To create the status information for positioning completion.
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo
motor must be at a stop.

Y1

X0

M

Y1

ABS transfer
mode

Positioning
completion

ABS transfer
mode

Completion of positioning

(g) Zero speed

To create the status information for zero speed.
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo
motor must be at a stop.

Y1

X1

M

Y1

ABS transfer
mode

Zero speed

ABS transfer
mode

Zero speed

(h) Torque limiting

To create the status information for the torque limiting mode.
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the torque
limiting must be off.

Y1

X2

M

ABS transfer
mode

Torque limiting mode

Torque limiting mode