13. OPTIONS AND AUXILIARY EQUIPMENT

(2) Brake unit parameter setting

Normally, when using the FR-BU2, changing parameters is not necessary. Whether a parameter can
be changed or not is listed below.

Parameter

No.

Name

Change

possible/

impossible

Remarks

0

Brake mode switchover

Impossible

Do not change the parameter.

1

Monitor display data selection

Possible

Refer to the FR-BU2-(H) Brake Unit
Instruction Manual.

2

Input terminal function selection 1

3

Input terminal function selection 2

77

Parameter write selection

78

Cumulative energization time
carrying-over times

CLr

Parameter clear

ECL Alarm history clear

C1

For manufacturer setting

Impossible

Do not change the parameter.

(3) Connection example

POINT

Connecting PR terminal of the brake unit to P terminal of the servo
amplifier results in brake unit malfunction. Always connect the PR
terminal of the brake unit to the PR terminal of the resistor unit.

(a) Combination with FR-BR resistor unit

NFB

ALM

RA1

MC

SK

MC

ON

OFF

EMG

Servo motor

thermal relay

RA2

(Note 7)

(Note 1)

Power

supply

N/

P/

BUE
SD

PR

B

C

A

SD

MSG

(Note 4)

(Note 6)

P

1

P
D
P

N
C

FR-BU2

FR-BR

Servo amplifier

P
PR

TH2

TH1

(Note 5)

MC

(Note 3)

(Note 8)

(Note 2)

(Note 9)

L

1

L

2

L

3

L

11

L

21

(Note 10)

RA1

RA1

3

13

SG

VDD

COM

ALM

10

18

CN1B

EMG

15