Options and auxiliary equipment – MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 242

Advertising
background image

13 - 13

13. OPTIONS AND AUXILIARY EQUIPMENT

(c) Precautions for wiring

The cables between the servo amplifier and the brake unit, and between the resistor unit and the
brake unit should be as short as possible. Always twist the cable longer than 5m (twist five times
or more per one meter). Even when the cable is twisted, the cable should be less than 10m. Using
cables longer than 5m without twisting or twisted cables longer than 10m, may result in the brake
unit malfunction.

Servo amplifier

Brake unit

5m or less

5m or less

Servo amplifier

Brake unit

10m or less

10m or less

P

N

P

N

P

PR

PR

P

N

P

PR

P

PR

Twist

Resistor unit

Resistor unit

P

N

Twist

P

(d) Cables

For the brake unit, HIV cable (600V grade heat-resistant PVC insulated wire) is recommended.

a) Main circuit terminal

Cable size

Crimping

terminal

N/ , P/ , PR,

Brake unit

Main

circuit

terminal

screw

size

N/ , P/ ,

PR,

Tightening

torque

[N m]

([lb in])

HIV cables,

etc. [mm

2

]

AWG

FR-BU2-15K

M4

5.5-4

1.5 (13.3)

3.5

12

FR-BU2-30K

M5

5.5-5

2.5 (22.1)

5.5

10

N/

P/

PR

Terminal block

FR-BU2-55K

M6

14-6

4.4 (38.9)

14

6

b) Control circuit terminal

POINT

Undertightening can cause a cable disconnection or malfunction.
Overtightening can cause a short circuit or malfunction due to damage to
the screw or the brake unit.

A

RES

PC

B

SD

BUE

C

MSG

SD

MSG

SD SD

Jumper

Terminal block

6mm

Sheath

Core

Wire the stripped cable after twisting to prevent the cable
from becoming loose. In addition, do not solder it.
Screw size: M3
Tightening torque: 0.5N m to 0.6N m
Cable size: 0.3mm

2

to 0.75 mm

2

Screw driver: Small flat-blade screwdriver
(Tip thickness: 0.4mm/Tip width 2.5mm)