Communication functions – MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 306

Advertising
background image

14 - 13

14. COMMUNICATION FUNCTIONS

(5) Operation mode selection (Command [8][B])

Command

Data No.

Description

Setting range

Frame length

[8][B]

[0][0]

Operation mode changing
0000: Exit from test operation mode
0001: Jog operation
0002: Positioning operation
0003: Motor-less operation
0004: Output signal (DO) forced output

0000 to 0004

4

(6) External input signal disable (Command [9][0])

Command

Data No.

Description

Setting range

Frame length

[9][0]

[0][0]

Turns off the external input signals (DI), external analog input
signals and pulse train inputs with the exception of EMG, LSP
and LSN, independently of the external ON/OFF statuses.

1EA5

4

[9][0]

[0][3]

Disables all output devices (DO).

1EA5

4

[9][0]

[1][0]

Enables the disabled external input signals (DI), external analog
input signals and pulse train inputs with the exception of EMG,
LSP and LSN.

1EA5

4

[9][0]

[1][3]

Enables the disabled external output signals (DO).

1EA5

4

(7) Data for test operation mode (Command [9][2] [A][0])

Command

Data No.

Description

Setting range

Frame length

[9][2]

[0][0]

Input signal for test operation

Refer to section
14.12.6

8

[9][2]

[A][0]

Forced output from signal pin

Refer to section
14.12.8

8

Command

Data No.

Description

Setting range

Frame length

[A][0]

[1][0]

Writes the speed of the test operation mode (jog operation,
positioning operation).

0000 to 7FFF

4

[A][0]

[1][1]

Writes the acceleration/deceleration time constant of the test
operation mode (jog operation, positioning operation).

00000000 to
7FFFFFFF

8

[A][0]

[1][2]

Clears the acceleration/deceleration time constant of the test
operation mode (jog operation, positioning operation).

1EA5

4

[A][0]

[1][3]

Writes the moving distance (in pulses) of the test operation mode
(jog operation, positioning operation).

80000000 to
7FFFFFFF

8

[A][0]

[1][5]

Temporary stop command of the test operation mode (jog
operation, positioning operation)

1EA5

4

Advertising