3 - 42

3. SIGNALS AND WIRING

(2) Digital output interface DO-1

A lamp, relay or photocoupler can be driven. Provide a diode (D) for an inductive load, or an inrush
current suppressing resistor (R) for a lamp load. (Permissible current: 40mA or less, inrush current:
100mA or less) A maximum of 2.6V voltage drop occurs in the servo amplifier.

(a) Inductive load

For use of internal power supply

For use of external power supply

COM

ALM, etc

SG

Load

Servo amplifier

VDD

24VDC

If the diode is not

connected as shown,

the servo amplifier

will be damaged.

COM

ALM, etc

SG

Load

Servo amplifier

VDD

24VDC

If the diode is not

connected as shown,

the servo amplifier

will be damaged.

Do not connect

VDD-COM.

(Note)
24VDC
10%

Note. If the voltage drop (maximum of 2.6V) interferes with the

relay operation, apply high voltage (up to 26.4V) from
external source.

(b) Lamp load

For use of internal power supply

For use of external power supply

Servo amplifier

COM

R

VDD

24VDC

SG

ALM, etc

(Note)
24VDC
10%

Servo amplifier

COM

R

VDD

24VDC

SG

ALM, etc

Do not connect

VDD-COM.

Note. If the voltage drop (maximum of 2.6V) interferes with the

relay operation, apply high voltage (up to 26.4V) from
external source.