Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 70

Advertising
background image

3 - 23

3. SIGNALS AND WIRING

(4) Power supply

Connector pin No.

Control

mode

Signal

Symbol

7kW or

less

11kW or

more

Functions/Applications

I/O division

P S T

I/F internal
power supply

VDD

CN1B

3

CN1B

3

Used to output 24V 10% to across VDD-SG.
When using this power supply for digital interface,
connect it with COM.
Permissible current : 80mA

Digital I/F power
supply input

COM

CN1A

9

CN1B

13

CN1A

9

CN1B

13

Used to input 24VDC for input interface.
Connect the positive terminal of the 24VDC external
power supply.
24VDC 10%

Open collector
power input

OPC

CN1A

11

CN1A

11

When inputting a pulse train in the open collector
system, supply this terminal with the positive ( ) power
of 24VDC.

Digital I/F
common

SG

CN1A

10
20

CN1B

10
20

CN1A

10
20

CN1B

10
20

Common terminal for input signals such as SON and
EMG. Pins are connected internally.
Separated from LG.

15VDC power
supply

P15R

CN1A

4

CN1B

11

CN1A

4

CN1B

11

Outputs 15VDC to across P15R-LG. Available as power
for TC, TLA, VC, VLA.
Permissible current: 30mA

Control common

LG

CN1A

1

CN1B

1

CN3

1, 11
3, 13

CN1A

1

CN1B

1

CN3

1, 11
3, 13

CN4

4

Common terminal for TLA, TC, VC, VLA, FPA, FPB, OP
,MO1, MO2 and P15R.
Pins are connected internally.

Shield

SD

Plate

Plate

Connect the external conductor of the shield cable.

Advertising