Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 64

Advertising
background image

3 - 17

3. SIGNALS AND WIRING

Control

mode

Signal

Symbol

Connector

pin No.

Functions/Applications

I/O

division

P

S

T

Speed selection 1

SP1

CN1A

8

<Speed control mode>

Used to select the command speed for operation.

When using SP3, make it usable by making the setting of

parameter No. 43 to 48.

DI-1

(Note) Input

signals

Speed selection 2

SP2

CN1B

7

Setting of

parameter

No. 43 to 48

SP3 SP2 SP1

Speed command

DI-1

0

0

Analog speed command (VC)

0

1

Internal speed command 1

(parameter No. 8)

1

0

Internal speed command 2

(parameter No. 9)

When speed

selection

(SP3) is not

used

(initial status)

1

1

Internal speed command 3

(parameter No. 10)

0

0

0

Analog speed command (VC)

0

0

1

Internal speed command 1

(parameter No. 8)

0

1

0

Internal speed command 2

(parameter No. 9)

0

1

1

Internal speed command 3

(parameter No.10)

1

0

0

Internal speed command 4

(parameter No. 72)

1

0

1

Internal speed command 5

(parameter No. 73)

1

1

0

Internal speed command 6

(parameter No. 74)

When speed

selection

(SP3) is made

valid

1

1

1

Internal speed command 7

(parameter No. 75)

Note. 0: off

1: on

<Torque control mode>

Used to select the limit speed for operation.

When using SP3, make it usable by making the setting of

parameter No. 43 to 48.

(Note) Input

signals

Setting of

parameter

No. 43 to 48

SP3 SP2 SP1

Speed limit

0

0

Analog speed limit (VLA)

0

1

Internal speed command 1

(parameter No. 8)

1

0

Internal speed command 2

(parameter No. 9)

When speed

selection

(SP3) is not

used

(initial status)

1

1

Internal speed command 3

(parameter No. 10)

0

0

0

Analog speed limit (VLA)

0

0

1

Internal speed command 1

(parameter No. 8)

0

1

0

Internal speed command 2

(parameter No. 9)

0

1

1

Internal speed command 3

(parameter No.10)

1

0

0

Internal speed command 4

(parameter No. 72)

1

0

1

Internal speed command 5

(parameter No. 73)

1

1

0

Internal speed command 6

(parameter No. 74)

When speed

selection

(SP3) is made

valid

1

1

1

Internal speed command 7

(parameter No. 75)

Speed selection 3

SP3

Note. 0: off

1: on

DI-1

Advertising