13 - 3

13. OPTIONS AND AUXILIARY EQUIPMENT

b. Losses of servo motor and servo amplifier in regenerative mode

The following table lists the efficiencies and other data of the servo motor and servo amplifier in

the regenerative mode.

Servo amplifier

Inverse efficiency[%]

Capacitor charging[J]

MR-J2S-10A

55

9

MR-J2S-10A1

55

4

MR-J2S-20A

70

9

MR-J2S-20A1

70

4

MR-J2S-40A

85

11

MR-J2S-40A1

85

12

MR-J2S-60A

85

11

MR-J2S-70A

80

18

MR-J2S-100A

80

18

MR-J2S-200A

85

40

MR-J2S-350A

85

40

MR-J2S-500A

90

45

MR-J2S-700A

90

70

MR-J2S-11KA

90

120

MR-J2S-15KA

90

170

MR-J2S-22KA

90

250

Inverse efficiency ( )

:Efficiency including some efficiencies of the servo motor and servo

amplifier when rated (regenerative) torque is generated at rated speed.

Since the efficiency varies with the speed and generated torque, allow for

about 10%.

Capacitor charging (Ec) :Energy charged into the electrolytic capacitor in the servo amplifier.

Subtract the capacitor charging from the result of multiplying the sum total of regenerative energies
by the inverse efficiency to calculate the energy consumed by the regenerative option.

ER [J]

Es Ec

Calculate the power consumption of the regenerative option on the basis of single-cycle operation
period tf [s] to select the necessary regenerative option.

PR [W] ER/tf

(3) Connection of the regenerative option

Set parameter No.2 according to the option to be used.
The MR-RB65, 66 and 67 are regenerative options that have encased the GRZG400-2 , GRZG400-1
and GRZG400-0.8 , respectively. When using any of these regenerative options, make the same
parameter setting as when using the GRZG400-2 , GRZG400-1 or GRZG400-0.8 (supplied
regenerative resistors or regenerative option is used with 11kW or more servo amplifier).

Parameter No.0

Selection of regenerative
00: Regenerative option or regenerative option is not used with 7kW or
less servo amplifier
Supplied regenerative resistors or regenerative option is used with
11kW or more servo amplifier
01: FR-RC, FR-BU2, FR-CV
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50 (Cooling fan is required)
08: MR-RB31
09: MR-RB51 (Cooling fan is required)
0E: When regenerative resistors supplied to 11kW or more are cooled by
cooling fans to increase capability