Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 93

Advertising
background image

3 - 46

3. SIGNALS AND WIRING

(7) Source input interface

When using the input interface of source type, all Dl-1 input signals are of source type. Source output
cannot be provided.

For use of internal power supply

For use of external power supply

SG

COM

24VDC

VDD

TR

R: Approx. 4.7

SON,

etc.

(Note)
For a transistor
Approx. 5mA

V

CES

1.0V

I

CEO

100 A

Switch

Servo amplifier

SG

COM

24VDC

200mA or more

R: Approx. 4.7

SON,etc.

Switch

Servo amplifier

Note. This also applies to the use of the external power supply.

When using the input interface of source type, all Dl-1 input signals are of source type. Source output
cannot be provided.
For 11kW or more, the source input interface cannot be used with the internal power supply. Always
use the external power supply.

CON2

MITSUBISHI

JP11

CON2

CON2

JP11

JP11

For sink input (factory setting)

For source input

(Note)

(Note)

Jumper

Jumper

Note. The jumper, which is shown black for the convenience of explanation, is actually white.