3 - 44

3. SIGNALS AND WIRING

(b) Differential line driver system

1) Interface

SD

PG(NG)

PP(NP)

Max. input pulse
frequency 500kpps

Servo amplifier

Am26LS31 or equivalent

Approx. 100

V

OH

: 2.5V

V

OL

: 0.5V

(Note)

10m (393.70in) or less

Note. Pulse train input interface is comprised of a photo coupler.

Therefore, it may be any malfunctions since the current is reduced when connect a resistance
to a pulse train signal line.

2) Conditions of the input pulse

0.9

PP PG

tc

tHL

tc

tLH

tF

tLH tHL 0.1 s
tc 1 s
tF 3 s

NP NG

0.1

(4) Encoder pulse output DO-2

(a) Open collector system

Interface

Servo amplifier

OP

5 to 24VDC

Photocoupler

SD

Max. output current : 35mA

LG

Servo amplifier

OP

SD

LG

Advertising