Pressure Systems, Inc. Model 9116 User’s Manual

Page 121

www.PressureSystems.com

Activate the Windows

®

control bar (left click the START icon). Select the SETTINGS line

followed by the CONTROL PANEL folder. In the CONTROL PANEL folder, select the
NETWORK icon. Once in the NETWORK setup, select the tab labeled CONFIGURATION.
Scroll through the list of installed configuration protocols. Select the one labeled ‘TCP/IP-
>xxxx
’ where xxxx will typically identify your Ethernet adapter card. There may be other TCP/IP
protocols listed for other items such as dial up adapters, these are not used for the
NetScanner

System Ethernet configuration. If the TCP/IP protocol is not listed in the

configuration menu, left click the ADD button. Continue by selecting to add a PROTOCOL.
Select MICROSOFT from the Manufacturers list. Then select TCP/IP from the networks
protocol list.

Once in the proper TCP/IP protocol setup, select the ‘IP Address’ tab. Click on the button to
enable the field ‘Specify IP Address.’ Once selected, the fields for IP address and Subnet will
be enabled. In the IP address, enter a TCP/IP address for your host computer. An IP address
of 200.200.200.001 will work if the Model 9116 is using the factory default IP address. If the
leftmost fields of the Model 9116 module IP addresses are different than the factory default of
200.20x.yyy.zzz then the leftmost fields of the host computer’s IP address must match the
module’s leftmost IP address field. In the Subnet field a value of 255.0.0.0 can be entered for
most configurations.

When these fields are entered, click the OK icons until Windows

®

prompts you to restart your

computer. (Windows

®

95/98 only). Once the computer has restarted, it should be capable of

communications with the Ethernet Model 9116 module.

6.1.2.3

Verifying Host TCP/IP Communications


At this point, the Model 9116 module should be configured to obtain its IP address through
either static (default) or dynamic IP addressing. The module’s IP address must be assigned
and known in order to proceed. The host computer has also been configured for TCP/IP
protocol and assigned an IP address compatible with the Model 9116 IP address. A simple
method to verify proper operation is through the ping utility. This is a simple TCP/IP utility that
is found in Windows

®

95/98/2000/XP/NT as well as most other TCP/IP packages. The ping

utility simply sends a test packet to the specified IP address and waits for reply to be returned.
Model 9116 Ethernet modules are programmed to reply to these ping requests.

To run the ping utility from Windows

®

95/98/2000/XP/NT, follow these steps. Left click the

Windows

®

START button. Move the mouse pointer to ‘RUN’ and left click on it. At the prompt

type ‘ping xxx.xxx.xxx.xxx’ where xxx.xxx.xxx.xxx represents the IP address of the device to
test. The IP address of an Ethernet Model 9116 module should be used. A small DOS window
will appear as the ping application executes. The ping program will either report that a reply
was received or that it failed to receive a reply. If the ping application reported receiving a reply,
the host computer and the Model 9116 module are both properly configured for TCP/IP
communications.

If an error free ping reply was not received, rerun the ping application using the IP address of
the host computer. This will verify if the TCP/IP protocol was properly configured on the host
computer. If a ping reply was not received, verify the TCP/IP installation steps for your host
computer. Also verify that the host computer is configured for the proper IP address and subnet
mask.