9. Component Checks Reset System After Lockout

If the oven enters safety lockout, the system must be

reset before attempting further operation or checkout.

The system will remain in safety lockout until it is re-

set. Shut system OFF. (Turn Heat switch OFF.) Wait

at least five minutes, then turn Heat switch ON.

10. Check Spark Ignition Circuit

The electronic module and step-up transformer in the

ignition module provide spark ignition at 15,000V (open

circuit). This circuit can be checked at the ignition

module as follows:
a. Turn OFF the gas flow at the manual shutoff valve.
b. Disconnect the ignition cable at the ignition mod-

ule terminal to isolate the circuit from the pilot

burner/ignitor sensor, and prepare a short jumper

lead using heavily insulated wire, such as a spare

ignition cable.

c. Energize the ignition module and touch one end of

the jumper firmly to the control board ground termi-

nal (GND). Do not disconnect the existing ground

lead. Move the free end slowly toward the stud

terminal to establish a spark and then pull the lead

wire slowly away from the stud. Note the length of

the gap at which arcing stops.

d. An arc length of 1/8” (3.2mm) or more indicates

satisfactory voltage output. Replace the ignition

module if no arc can be established or if the maxi-

mum gap is less than 1/8” (3.2mm), and power to

the ignition module input terminals was correct.

WARNING

Do Not touch either stripped end of jumper or stud

terminal. This is a very high voltage circuit and

electrical shock can result. Perform the test im-

mediately upon energizing the system, before the

ignition module enters safety lockout and inter-

rupts the spark circuit.

11. Check Spark Ignitor

If the troubleshooting procedure indicates a problem

with the ignitor/sensor, check the spark ignitor and the

ignition cable connections and continuity as follows:
Check Ignitor/Sensor
a. Check the ignitor spark gap to make certain it is

correct, 1/8” (3.2mm). If necessary, use a

needlenose pliers and carefully bend the tip of the

outer electrode to the correct gap.

b. Check that the pilot flame is properly adjusted.
Check Igniton Cable
a. The ignition cable must not touch metal surfaces

or current-carrying wires. Use ceramic standoff

insulators, if necessary.

b. Check the length of the ignition cable. It must not

exceed 3 ft. (0.9 m).

c. Check the connections to the ignitor and ignition

module terminals. All connections must be clean

and tight. Loose connections may not conduct a

flame current even though the ignition spark is sat-

isfactory. Check the electrical continuity of the

cable. Replace the cable if it is damaged or dete-

riorated.

d. If no spark or a weak spark occurs, but the spark

ignition circuit checked normally, disconnect the

ignition cable at the ignitor/sensor and measure

the arc from the cable end to the ignitor stud. Fol-

low the same general procedures and observe the

same cautions as in Step 10, Check Spark Igni-

tion Circuit, above.

If the arc is correct, replace the ignitor/sensor.
If the arc is less than it should be, disconnect the igni-

tion cable and use a jumper wire from the ignition mod-

ule stud terminal. If the spark is normal, replace the

ignition cable. If the arc is still smaller than normal,

replace the ignition module.

Q. Checking the Gas Pressures
All gas pressures should be checked using a manometer

at the supplied pressure taps, as follows:
•

Inlet pressure can be checked at the inlet pressure tap

on the combination gas valve. See Figure 72 (on Page

98).

•

Regulated pressure can be checked at the outlet pres-

sure tap on the combination gas valve. See Figure 72

(on Page 98).
Current PS555/570-series ovens provide an additional

regulated pressure tap in the main gas line, just before

the line enters the burner. This allows you to connect

a SECOND manometer downstream of the modulating

valve to check that the valve is functioning properly.

We encourage you to use this tap to diagnose prob-

lems with the modulating valve whenever possible.

•

Pilot gas pressure can be checked at the pilot pres-

sure tap. For ovens with a Wayne burner, the tap is

located on the pilot line. For PS360EWB/WB70 ovens

with a Midco burner, the tap is located on the end of

the pilot orifice fitting. Refer to the illustrations on Pages

88-90.
Some older ovens (pre-1994) with Wayne burners may

not be equipped with a pilot pressure tap. If you en-

counter problems with an erratic pilot (see Servicing

the Combination Valve on Page 98), it may be neces-

sary to install a tap. Middleby offers Service Kit P/N

30185 which includes the pilot pressure tap and in-

structions. A copy of the instructions are also provided

in the Appendices section.
IMPORTANT: Any older oven that has a pilot pressure

tap installed should have the combination gas valve re-

placed with a current version at the same time. Com-

bination valves used prior to 1994 are beyond the scope

of this Manual and may not be compatible with the tap.