PS536

Thermocouples on these ovens are located inside the ma-

chinery compartment. They are secured in place by a sheet

metal screw that traps the thermocouple flange against the

wall of the compartment. See Figure 7.

NOTE FOR HIGH LIMIT THERMOCOUPLES:

PS536 ovens have two thermocouples, one mounted

above the other. The upper thermocouple senses the

oven temperature and is connected to the temperature

controller. The lower thermocouple is connected to the

high limit control module. Either thermocouple can be

replaced using this Kit.

1. Loosen the sheet metal screw that holds the thermo-

couple flange to the wall of the machinery compart-

ment.

2. Pull the thermocouple out of the machinery compart-

ment. Disconnect the thermocouple leads.

3. Install the new thermocouple so that its flange fits firmly

against the wall of the machinery compartment. Tighten

the sheet metal screw so that its head holds the ther-

mocouple flange securely in place.
NOTE: PS536 ovens do not use a thermocouple mount-

ing tube, so it is CRITICAL that the thermocouple flange

is securely fastened to the wall of the machinery com-

partment.

4. Route the thermocouple leads away from the ignition

cable. Connect the leads as shown in Figure 8.

Figure 7

Thermocouple Installation - PS536

Thermocouple

Sheet

metal

screw

Machinery

compartment

wall

Thermocouple

flange

Plenum

wall

Screw head holds thermocouple

flange in place

Figure 8

Thermocouple Wiring - PS536

Digital Temperature Controller

High Limit Control Module

Red

White

Shielded

ground lead

Shielded

ground lead

Red

White

Temperature-

sensing

thermocouple

High limit

thermocouple

Appendix - Instructions for Service Kits 33984 and 33985 -

Oven Thermocouple Kit, 11/01

SECTION 3 - SERVICING COMPONENTS