B. PS360-series ovens
All PS360-series ovens are equipped with two blower motors.
•

All gas ovens have motors rated at 230V, single-phase.

•

All electric ovens built before 8/02 have three-phase

motors.

•

All electric ovens built 8/02 or later that operate on a

supply voltage of 208-240V have single-phase motors.

•

All electric ovens built 8/02 or later that operate on supply

voltages above 240V have three-phase motors.

Blower motors are protected by:
•

A built-in thermal overload protection device.

•

For ovens with single-phase blower motors: Two 9A

fuses. Fuse location is shown in Figure 35.

•

For ovens with three-phase blower motors: Three 5A

fuses. Fuse location is shown in Figure 36.

In addition, each motor contains a centrifugal safety switch

that prevents the burner/heating elements from activating if

either motor is not operating. See Blower Motor Centrifugal

Safety Switch on Page 80.
The blower wheel is directly connected to the motor shaft.

A heat slinger, also mounted on the motor shaft, helps to

keep heat away from the motor bearings. If the motor is

stopped when the temperature in the compartment is over

180°F/82°C, the bearings can be damaged.

Blower motors

Part Number

Description

27381-0023

1 Ph, 1/3 hp (PS310, -314, -360, -360S)

27381-0024

3 Ph, 1/3 hp (PS310, -314, -360)

27381-0054

1 Ph, 1/4 hp (PS360Q)

27381-0075

1 Ph, 1/2 hp (PS360WB)

31432

1 Ph, 1 hp (PS360EWB, -WB70)

Blower wheels

Part Number

Part Number

(clockwise) (counter-clockwise) Description

22523-0002

22523-0003

9-3/16” / 233mm dia. (PS310, -314,

-360, -360Q, -360S, -360WB)

35603

35604

9-1/8” / 232mm dia. (PS360EWB)

36014

36015

8-1/4” / 210mm dia. (PS360EWBQ)

31599

31600

9-7/8” dia. / 251mm (PS360WB70)

Other components

Part Number

Description

27396-0005

Heat slinger

42400-0101

Blower wheel puller tool

1. Part number reference

Figure 35

Blower motor fuses - single-phase motors

Figure 36

Blower motor fuses - three-phase motors

Left motor

fuses - 9A

Right motor

fuses - 9A

Control

fuse - 5A

Left motor

fuses - 5A

Right motor

fuses - 5A

Control

fuse - 5A

Transformer fuses

(480V electric

ovens only)

2. Blower balancing

All blower wheels are balanced at the factory. Any

blower wheel found to be out of balance should be re-

placed. Vibration from an out-of-balance wheel can

cause poor baking and premature motor bearing fail-

ure. Note that vibrations can also be caused by other

sources, including defective motor bearings and loose

motor mounting bolts.

SECTION 3 - SERVICING COMPONENTS

Advertising
This manual is related to the following products: