12

PS555G and PS570G rear wall thermocouples

with left-side terminal block connections

Thermocouples on these ovens are located on the rear wall.

They are secured in place by two screws that are inserted

through the holes in the thermocouple flange. The ovens

are equipped with a three-lead, flanged thermocouple iden-

tical to the one in this Kit.

NOTE FOR HIGH LIMIT THERMOCOUPLES:

These ovens have a high limit thermocouple installed in

the last mounting hole at the exit end of the oven.
The thermocouple supplied in this Kit can be used to

replace ANY of the temperature-sensing or high limit ther-

mocouples on the oven.

1. Remove the rear shrouds. Then, remove the cover over

the left blower motor. This allows access to the ther-

mocouples on the rear wall, and to the terminal block

inside the blower motor compartment.
Note that the thermocouples on these ovens are all

connected to the terminal block inside the left blower

motor compartment. It is not necessary to access the

right blower motor compartment.

2. Remove the screws that hold the thermocouple to the

wall. Slide the thermocouple out of its mounting hole.

3. Disconnect the thermocouple leads from the terminal

block. Remove and discard the thermocouple.

4. Install the new thermocouple into its mounting hole.

Fasten it in place with the supplied #6 x 3/8” screws.

5. Wire the thermocouple as shown in Figure 16. Note

that the terminals are labeled - “TC” for temperature-

sensing thermocouple leads, “G” for ground leads, and

“HL” for high limit thermocouple leads.

6. Use the kit-supplied nylon clamp and #10-16 x 3/4”

screw to secure the thermocouple leads so that they

will clear the shrouds, blower belts, and pulleys.

7. Replace all shrouds onto the oven.

Middleby Cooking Systems Group • 1400 Toastmaster Drive • Elgin, IL 60120 • (847) 741-3300 • FAX (847) 741-4406

Middleby Corporation Service Hotline 1-800-238-8444

Figure 16

Thermocouple Wiring - PS555G and PS570G

To temperature

controller

To high limit

control module

White

(hi lim)

Red

(hi lim)

Ground

leads (all)

Red

(temp)

White

(temp)

To mounting screw

for high limit

control module

To ground

terminal on temp

controller