Gas conversion kit for middleby marshall ovens, English, Es pañol – Middleby Marshall PS200 series User Manual

Page 120: Natural gas to propane operation

Advertising
background image

119

ENGLISH

-

page

1

E

S

PAÑOL

- página

7

1

Instructions for Service Kits 42810-0119, 42810-0122, 42810-0123, 42810-0124, 43062, 44665

Gas Conversion Kit for Middleby Marshall Ovens

Natural Gas to Propane Operation

KIT COMPONENTS:

Qty.

PS200

PS220/224

PS310/360

PS360WB

PS360WB70/EWB

PS555

PS570S

Description

1 42810-0122 42810-0123 42810-0119 42810-0124

44665

43062

42810-0124 KIT, GAS CONVERSION, NATURAL

TO PROPANE

1 22176-0007 22176-0017 22176-0003 22176-0015

31980

43060

22176-0015 ORIFICE, MAIN

0.1285”/3.26mm

0.113”/2.87mm

0.134”/3.40mm

0.152”/3.86mm

0.165”/4.19mm

0.141”/3.58mm

0.152”/3.86mm

1

< - - - - - - - - - - - - - - - - - - - - - - - - 22174-0010 - - - - - - - - - - - - - - - - - - - - - - - - >ORIFICE, PILOT

0.018”/0.45mm

1 22174-0009 22174-0009 22174-0009 22174-0009 22174-0009 *

NONE *

22174-0009 * ORIFICE, BYPASS (HIGH-FLAME)

0.038”/0.97mm/

0.038”/0.97mm/

0.038”/0.97mm/

0.038”/0.97mm/

0.038”/0.97mm/

0.038”/0.97mm/

#62 drill

#62 drill

#62 drill

#62 drill

#62 drill

#62 drill

1

< - - - - - - - - - - - - - - - - - - - - - - - - 28092-0018 - - - - - - - - - - - - - - - - - - - - - - - - >KIT, GAS CONTROL VALVE SPRING

- PROPANE

1

< - - - - - - - - - - - - - - - - - - - - - - - - 22500-0065 - - - - - - - - - - - - - - - - - - - - - - - - >LABEL, PROPANE (RED)

1

< - - - - - - - - - - - - - - - - - - - - - - - - 22500-0123 - - - - - - - - - - - - - - - - - - - - - - - - >LABEL, GAS CONVERSION

1

< - - - - - - - - - - - - - - - - - - - - - - - - 22501-0007 - - - - - - - - - - - - - - - - - - - - - - - - >TAG, GAS CONTROL CONVERSION

1

< - - - - - - - - - - - - - - - - - - - - - - - - 88210-0069 - - - - - - - - - - - - - - - - - - - - - - - - >INSTRUCTIONS

NOTE: The bypass orifice is not used if the oven is equipped with a modulating gas valve. These ovens include:
•

PS360EWB (all)

•

PS555 (all)

•

PS570S (units produced 4/00 or later)

For additional information, refer to Part III of these instructions (Bypass Orifice Conversion).

WARNING

THIS CONVERSION KIT IS TO BE INSTALLED BY A MIDDLEBY MARSHALL AUTHORIZED SERVICE AGENT

IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AND ALL CODES AND REQUIREMENTS

OF THE AUTHORITY HAVING JURISDICTION. FAILURE TO FOLLOW INSTRUCTIONS COULD RESULT IN

SERIOUS INJURY OR PROPERTY DAMAGE. THE AUTHORIZED SERVICE AGENT PERFORMING THIS

WORK ASSUMES RESPONSIBILITY FOR THIS CONVERSION.

Middleby Cooking Systems Group • 1400 Toastmaster Drive • Elgin, IL 60120 • USA • (847) 741-3300 • FAX (847) 741-4406

*

P/N 88210-0069 • Rev. C • V1 • 8/00

WARNING

BEFORE PERFORMING ANY SERVICE WORK, THE ELECTRICAL POWER SUPPLY AND THE GAS SUP-

PLY MUST BE TURNED OFF.

IMPORTANT

THIS CONVERSION KIT IS INTENDED FOR AGA-, CGA-, AND CSA-APPROVED MIDDLEBY

MARSHALL GAS-FIRED OVENS OPERATING AT ALTITUDES UP TO 5000 FT. (1524m).

FOR OVENS INSTALLED AT ALTITUDES ABOVE 5000 FT. (1524m), CONSULT THE FAC-

TORY BEFORE INSTALLING THIS KIT.
THIS KIT MAY NOT BE USED WITH CE-APPROVED MIDDLEBY MARSHALL OVENS.

FOR THESE OVENS, FOLLOW THE GAS CONVERSION INSTRUCTIONS IN THE INSTAL-

LATION SECTION OF THE OVEN’S OWNER’S OPERATING AND INSTALLATION MANUAL.

SECTION 3 - SERVICING COMPONENTS

Appendix - Instructions for All Gas Conversion Kits

for Ovens with Wayne Burner, Natural Gas to Propane, 8/00