Middleby Marshall PS200 series User Manual

Page 149

Advertising
background image

148

SECTION 3 - SERVICING COMPONENTS

Figure 90

Figure 92

Figure 91

2. PS310/360-series contactor replacement

•

Remove the two Phillips-head screws holding the

cover in place. Then, remove the cover.

•

Remove the six terminal lug screws. This proce-

dure must be followed when replacing the coil or

any one contact tube.

•

The coil and contact tubes will now pull straight

out from the base. The coil or any individual con-

tact tube can now be replaced.
NOTE: When replacing the mercury contactor into

the oven, the wider tube ends must be pointing UP.

The tubes must ALWAYS be mounted in a vertical

position.

•

Replace the cover and attach it with the two Phillips-

head screws. Note that the cover and base are

marked to show correct orientation.