SECTION 3 - SERVICING COMPONENTS

6. Changing Heating Elements

NOTE: Wires going from the controller assembly

contactor to the heating elements are rated at 392°F/

200°C. DO NOT, under any circumstances, use a wire

of lesser rating or quality.
To remove the element:
•

Remove the blower belt on the affected side of the

oven.

•

Remove the wireway cover.

Figure 83

PS555 electric oven heating element removal

Remote

terminal blocks

Hex

bolt

Lock

washer

Flat

washer

Wireway

cover

Heating

element

assembly

Flat

washer

Hex head

screw

Hex head

screw

•

Disconnect the electrical lead connections from the

front of the oven to the remote terminal blocks on

the back wall. Then, disconnect the leads from

the remote terminal blocks to the elements.

•

Remove the 8 hex bolts that hold the rear wall panel

to the body of the oven. Once removed, DO NOT

lay the panel on either its front or back side. This

can damage the heating elements, blower fan and

bearings. The panel should be kept upright.

•

Remove the two hex head screws that hold the

element assembly to the back wall.

•

When replacing the rear oven panel, be sure to use

a high-temperature never-seize lubricant on the 8

hex bolts that hold the panel in place.

It is also possible to check for an open element using

an ampmeter. Any current through the element indi-

cates that the element is not open.