68

V. BLOWERS
A. PS200-series ovens
All PS200 ovens are equipped with one 1/3hp blower mo-

tor. The motor indirectly drives a pulley on the shaft of the

blower fan with a fan belt.
Two main designs exist for the PS200 indirect fan drive

assembly:
•

Early design, used through 6/90. This design used

1/2” (12.7mm) bore flange mount bearings and a 1/2”

(12.7mm) diameter blower fan shaft. See Figure 25.

•

Current design, used 7/90 and later. This design uses

5/8” (15.9mm) pillow block bearings and a 5/8” (15.9mm)

diameter blower fan shaft. See Figure 26.

Blower motors on both versions are rated for 208-240V,

single-phase, and are protected by:
•

A built-in thermal overload protection device.

•

Two 9A fuses on the inside of the machinery compart-

ment door. Fuse location is shown in Figure 27.

In addition, the blower fan is protected by an air pressure

saftety switch that prevents the burner/heating elements

from activating if the fan is not rotating. See Air Pressure

Safety Switch on Page 81.

Figure 25

Early-style PS200 indirect drive assembly

Figure 26

Current PS200 indirect drive assembly

Direction of rotation

(viewed from

rear of oven)

Direction of rotation

(viewed from

rear of oven)

Figure 27

Blower motor fuses

Early version components
NOTE: If an early-version PS200-series oven has a

failed fan shaft, upgrade the oven to the current drive

assembly using Kit P/N 49810-0121.
Part Number

Description

22230-0072

Pulley, 1/2” / 12.7mm bore

22071-0019

Bearing, 1/2” / 12.7mm bore, flange

mount

37900-0094

Fan shaft alignment tool (early)

27381-0066

Motor, 1/3 hp, 200-240V, 50/60Hz ,1 Ph

22181-0034

Fan belt

Current version components
Part Number

Description

35900-0232

Shaft, blower fan

22230-0073

Pulley, 5/8” / 15.9mm bore

22072-0025

Bearing, 5/8” / 15.9mm bore, pillow

block mount

27399-0003

Blower fan, 16” / 0.4m diameter

37900-0106

Fan shaft alignment tool (current)

49810-0121

Indirect drive upgrade kit (upgrades

early-style version to current version)

49810-0018

Fan shaft service kit (includes 2 bear-

ings, 1 shaft, and alignment tool )

27381-0066

Motor, 1/3 hp, 200-240V, 50/60Hz ,1 Ph

22181-0034

Fan belt

1. Part number reference

Control

fuse

Blower

motor

fuses

SECTION 3 - SERVICING COMPONENTS