Middleby Marshall PS200 series User Manual

Page 81

Advertising
background image

80

Figure 49 - PS360-series blower motor centrifugal safety switch

Switch

VI. BLOWER MOTOR CENTRIFUGAL SAFETY SWITCH

(PS360-SERIES)

Middleby ovens have a safety feature that prevents the

burner/heating elements from activating if the blower(s) are

not in operation. On PS360-series ovens, this feature is

controlled by a centrifugal switch mounted inside each

blower motor. If either motor is not operating, the burner/

heating elements cannot activate.
The centrifugal switch is a normally-closed (NC) limit switch

mounted inside the rear of each blower motor. See Figure

49. When the motor is not running, the centrifugal switch

weight holds the switch open. As the motor reaches full

speed, the weight moves away from the switch permitting

the contacts to close. When the switch contacts of BOTH

blower motors are closed, the heat circuit is completed,

allowingthe burner/heating elements to activate.
If a blower motor is not operating, the switch will not close

and the circuit remains open, preventing burner/heating el-

ement activation.
A. Part Number Reference - Blower Centrifugal Switch

On all PS360-series blower motors, the centrifugal

switch can be replaced with switch P/N 27270-0144.

B. Troubleshooting
1. To access the switch, remove the rear motor wiring

cover plates. See Figure 49.

2. When the switch is operating properly, both sides of

the brown wires coming from the switch should be “hot”

when the motor is at full RPM.

3. No adjustment can be made to the switch. If it is not

operating properly, it must be replaced.

VII. BURNER BLOWER MOTOR CENTRIFUGAL SAFETY

SWITCH (PS200-SERIES GAS, PS310, PS314,

PS360, PS360WB, PS570S)

Middleby gas ovens with a 120V burner blower motor have

a centrifugal safety switch that prevents burner activation if

the burner blower motor is not in operation. This includes:
•

Most PS360-series ovens (except PS360WB70 and

PS360EWB);

•

PS200-series gas ovens (except units produced with

the modulating gas system);

•

All Model PS570S ovens.

Ovens with a 208/240V burner blower motor use a separate

air pressure safety switch to prove motor operation. See

Air Pressure Safety Switch on Page 81.
The centrifugal switch is a normally-closed (NC) limit switch

mounted inside each blower motor. When the motor is not

running, the centrifugal switch weight holds the switch open.

As the motor reaches full speed, the weight moves away

from the switch permitting the contacts to close. This com-

pletes the heat circuit, allowingthe burner to light.
If the burner blower motor is not operating, the switch will

not close and the circuit remains open, preventing burner

activation.
No adjustment can be made to the switch. If it is not oper-

ating properly, the burner blower motor must be replaced.

SECTION 3 - SERVICING COMPONENTS

Advertising
This manual is related to the following products: