Middleby Marshall PS200 series User Manual

Page 90

Advertising
background image

89

SECTION 3 - SERVICING COMPONENTS

Figure 56

PS360EWB or PS360WB70 gas train with Midco burner

Figure 57

PS360EWB or PS360WB70 gas train with Wayne burner

Air shutter

42810-0087

Burner blower

and motor assy,

208/240V

27170-0287

Manual shutoff

valve, 3/4”

23115-0010

3/4” union

23051-0004

Combination gas

control valve, 3/4”

32569

PS360EWB ONLY:

M520 modulating

valve, 3/4”

32570

PS360WB70 ONLY:

Solenoid valve, 3/4”

31500

Pilot

pressure

tap

30185

Air shutter

36830

Burner blower

motor,

208/240V

32195

Manual shutoff

valve, 3/4”

23115-0010

3/4” union

23051-0004

Combination gas

control valve, 3/4”

32569

PS360EWB ONLY:

M420 modulating

valve, 3/4”

32570

PS360WB70 ONLY:

Solenoid valve, 3/4”

31500

Pilot orifice

See chart on

Page 69

Pilot

pressure

tap

Pilot line

(1/4” aluminum tubing)

15125-0002

(per foot)

PS360WB70

ONLY:

Bypass line

(1/4” aluminum

tubing)

15125-0002

(per foot)

Air tube

(silicone rubber)

22450-0297

(per foot)

TO NEGATIVE (-)

SIDE OF AIR

SWITCH

Air tube

(silicone rubber)

22450-0297

(per foot)

TO POSITIVE (+)

SIDE OF AIR

SWITCH

PS360WB70 ONLY:

Bypass line

(1/4” aluminum tubing)

15125-0002

(per foot)

Pilot line

(1/4” aluminum

tubing)

15125-0002

(per foot)

Main orifice

See chart on

Page 69

Advertising