SECTION 3 - SERVICING COMPONENTS

2. Checking the thermocouple with a DC millivolt meter

It is possible to check that a thermocouple is reading

accurately by using a multimeter set to read DC milli-

volts. At 32°F/0°C the thermocouple should read

0 mVDC. This can be checked by inserting the ther-

mocouple into an ice bath for several minutes. At 72°F/

22°C the reading should be 1.134mVDC.
You can use the chart below by checking the tempera-

ture at the thermocouple’s junction terminals. This is

called the Junction Temperature.

Figure 24 - Thermocouple millivolt readings at various operating and junction temperatures